Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Kizilçay AO et al. | 2024 | 動物, rabbit/New Zealand | - | 1,800–2,100 MHz | - | - | 移動体通信システム, 携帯電話 |
Poulletier de Gannes F et al. | 2017 | 動物, 身体の一部 | - | 1,800–1,960 MHz | - | - | 携帯電話, 移動体通信システム, GSM, UMTS |
Sirav B et al. | 2016 | 動物, rat/Wistar albino, 全身 | permeability of the blood brain barrier | 900 MHz | 0.02 W/kg | continuous for 20 minutes | 携帯電話, GSM, 移動体通信システム |
Masuda H et al. | 2015 | 動物 | - | 1,457 MHz | - | - | 移動体通信システム, PDC, マイクロ波 |
Soderqvist F et al. | 2015 | ヒト, 身体の一部: right head side | blood brain barrier permeability | 890 MHz | 0.2–2 W/kg | continuous for 1 hour | 携帯電話, 移動体通信システム |
Tang J et al. | 2015 | 動物, rat/Sprague-Dawley, 身体の一部: head | relationship between memory function, blood brain barrier permeability and the mkp-1/ERK pathway in the rat brain | 900 MHz | 0.016–2 W/g | continuous for 3 h/day for 14 days | 携帯電話, 移動体通信システム |
Nittby H et al. | 2011 | 動物, ラット/Fischer 344, 全身 | 血液脳関門の透過性 | 50 Hz | 0.37–0.44 mW/kg | continuous for 2 h | デジタル携帯電話, GSM, 移動体通信システム, RF, PW パルス波, 磁界, 低周波電磁界, 50/60 Hz (AC) |
de Gannes FP et al. | 2009 | 動物, rat/Fischer 344, 身体の一部: head | permeability of blood-brain barrier and neuron degeneration | 900 MHz | 0.14–2 W/kg | continuous for 2 hr | 携帯電話, デジタル携帯電話, GSM, 移動体通信システム |
Hirota S et al. | 2009 | 動物, rat/Sprague-Dawley, 身体の一部: head | microcirculation in brain | 1,439 MHz | 0.16–4.8 W/kg | continuous for 10 min | TDMA, 移動体通信システム, RF, マイクロ波 |
Masuda H et al. | 2009 | 動物, rat/Fischer 344, 全身 | permeability of blood-brain barrier | 915 MHz | 0.02–2 W/kg | continuous for 2 h | 移動体通信システム, デジタル携帯電話, GSM |
Sirav B et al. | 2009 | 動物, rat/Wistar albino, 全身 | permeability of blood-brain barrier | 900 MHz | - | continuous for 20 min | 移動体通信システム, 携帯電話, RF, CW 連続波 |
Söderqvist F et al. | 2009 | ヒト, 身体の一部: head | integrity of blood-brain barrier and blood-cerebrospinal fluid barrier | 890 MHz | 1 W/kg | continuous for 30 min | 移動体通信システム, デジタル携帯電話, GSM |
McQuade JM et al. | 2009 | 動物, rat/Fischer 344 CD-VAF, 全身 | permeability of blood-brain barrier | 915 MHz | 0.0018–20 W/kg | continuous for 30 min | 携帯電話, GSM, 移動体通信システム, RF, CW 連続波, PW パルス波 |
Finnie JW et al. | 2009 | 動物, mouse, 全身 | aquaporin-4 expression in the brain (as marker for blood-brain barrier permeability) | 900 MHz | 4 W/kg | continuous for 60 min | 携帯電話, GSM, 移動体通信システム, PW パルス波 |
Nittby H et al. | 2009 | 動物, rat/Fischer 344, 全身 | blood-brain barrier permeability and neuronal damage | 915 MHz | 0.12–120 mW/kg | continuous for 2 hr | 携帯電話, GSM, 移動体通信システム, マイクロ波 |
Eberhardt JL et al. | 2008 | 動物, rat/Fischer 344, 全身 | blood-brain barrier permeability and nerve cell damage | 900 MHz | 0.12–120 mW/kg | continuous for 2 h | 携帯電話, GSM, 移動体通信システム |
Grafstrom G et al. | 2008 | 動物, rat/Fischer 344, 全身 | neuronal damage, blood-brain barrier permeability and effects on ageing process and memory | 900 MHz | 0.6–60 mW/kg | 2 hr/week for 55 weeks | 携帯電話, デジタル携帯電話, GSM, 移動体通信システム |
Masuda H et al. | 2007 | 動物, rat/Sprague-Dawley, 身体の一部: head | microcirculation in brain | 1,439 MHz | 0.6–4.8 W/kg | intermittent, 10 min on/20 min off, for 90 min | デジタル携帯電話, PDC, TDMA, 移動体通信システム, 携帯電話 |
Masuda H et al. | 2007 | 動物, rat/Sprague-Dawley, 身体の一部: head | microcirculation in brain | 1,439 MHz | 0.64–2.4 W/kg | repeated daily exposure, 60 min/day, 5 days/week, for 4 weeks | デジタル携帯電話, PDC, TDMA, 移動体通信システム, 携帯電話 |
Finnie JW et al. | 2006 | 動物, mouse/BALB/c, 全身 | blood-brain barrier permeability | 900 MHz | 4 W/kg | repeated daily exposure, 60 min/day, for 7 days | デジタル携帯電話, GSM, 移動体通信システム |
Finnie JW et al. | 2006 | 動物, mouse/BALB/c, 全身 | blood-brain barrier permeability | 900 MHz | 4 W/kg | repeated daily exposure for 60 min/day from day 1 to day 19 of gestation | GSM, 移動体通信システム |
Persson BRR et al. | 2005 | 動物, rat/Fischer 344, 全身 | - | 915 MHz | 0.2–200 mW/kg | not specified in the article | デジタル携帯電話, GSM, 移動体通信システム, マイクロ波, CW 連続波, PW パルス波 |
Vojtisek M et al. | 2005 | 動物, rat/Wistar, 身体の一部: head | blood-brain barrier permeability (manganese in brain) | 900 MHz | - | continuous for 30 min | 移動体通信システム, 携帯電話 |
Franke H et al. | 2005 | 無傷細胞/細胞培養, model of blood-brain barrier (consisting of astrocytes and capillary endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.8 GHz | 0.3–0.46 W/kg | continuous for up to 5 days | GSM, 移動体通信システム, マイクロ波 |
Kuribayashi M et al. | 2005 | 動物, rat/Fischer 344, 身体の一部: head (nose) | blood-brain barrier | 1,439 MHz | 0.29–6 W/kg | repeated daily exposure, 90 min/day, 6 days/week, for 1 or 2 weeks | PDC, TDMA, 移動体通信システム |
Franke H et al. | 2005 | model of blood-brain barrier (consisting of porcine brain microvascular endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.966 GHz | 1.64 W/kg | continuous for 1 up to 3.5 days | UMTS, 移動体通信システム |
Salford LG et al. | 2003 | 動物, rat/Fischer 344, 全身 | permeability of blood-brain-barrier | 915 MHz | 2–200 mW/kg | continuous for 2 hours | GSM, 移動体通信システム, マイクロ波 |
Finnie JW et al. | 2002 | 動物, mouse/C57BL/6NTac, 全身 | blood-brain barrier permeability | 900 MHz | 0.25–4 W/kg | repeated daily exposure for 60 min/day, 5 days/week for 2 years | GSM, 移動体通信システム, マイクロ波 |
Finnie JW et al. | 2001 | 動物, mouse/C57BL/6NTac, 全身 | blood-brain barrier permeability | 898.4 MHz | 4 W/kg | continuous for 60 min | GSM, 移動体通信システム |
Tsurita G et al. | 2000 | 動物, rat/Sprague-Dawley, 身体の一部: head | permeability of the blood-brain barrier and morphological changes of the cerebellum | 1.439 GHz | 0.25–20 W/kg | repeated daily exposure for 1 h/day for 5 consecutive days and 2 days of rest, for 2 or 4 weeks | デジタル携帯電話, PDC, TDMA, 移動体通信システム |
Schirmacher A et al. | 2000 | model of blood-brain barrier (consisting of astrocytes and capillary endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.8 GHz | 0.3–0.46 W/kg | continuous for 4 days | GSM, 移動体通信システム |
Persson BRR et al. | 1997 | 動物, rat/Fischer 344 | permeability of blood-brain barrier | 915 MHz | 8 mW/kg–8.3 W/kg | continuous for 2 min to 960 min | GSM, TDMA, 移動体通信システム, マイクロ波 |
Fritze K et al. | 1997 | 動物, rat/Wistar, 身体の一部: head | permeability of the blood-brain barrier | 900 MHz | 0.3–7.5 W/kg | continuous for 4 h | GSM, 移動体通信システム, マイクロ波 |
Salford LG et al. | 1994 | 動物, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.016–5 W/kg | continuous for 2 h | GSM, 移動体通信システム, マイクロ波 |
Salford LG et al. | 1993 | 動物, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.33–3.3 W/kg | not specified | デジタル携帯電話, 移動体通信システム, マイクロ波 |
Persson BR et al. | 1992 | 動物, rat/Sprague-Dawley & Fischer 344, 全身 | permeability of the blood-brain barrier | 915 MHz | - | continuous for 2 h | GSM, 移動体通信システム, マイクロ波, 磁界, 静磁界 |
このウェブサイトはクッキー(Cookies)を使って、最善のブラウジングエクスペリエンスを提供しています。あなたがこのウェブサイトを継続して使用することで、私たちがクッキーを使用することを許可することになります。