この研究は、ウィスター雄ラット(70日齢)を用いて、肝臓の酸化状態に対するマイクロ波電磁界(MW;2.45GHz)ばく露の影響を調べた。ばく露群、擬似ばく露群(各群n=6)は、1日2時間、35日間のばく露(擬似ばく露)を受けた。
影響評価項目として、グルタチオンペルオキシダーゼ(GPx)・スーパーオキシドジスムターゼ(SOD)・カタラーゼ(CAT)の活性、マロンジアルデヒド(MDA)濃度、肝機能に関する血清生化学パラメータを測定した。その結果、ばく露群では、擬似ばく露群に比べ、GPxおよびSODのレベルは低下し、CATレベルは上昇した;ばく露群では、擬似ばく露群に比べ、MDAレベルが上昇し、肝機能に関する血清生化学パラメータの変化が観察された、と報告している。
The detailed summary of this article is not available in your language or incomplete. Would you like to see a complete translation of the summary? Then please contact us →
To examine the influence of exposure to microwaves (2.45 GHz) or to the radiofrequency field of a mobile phone (900 MHz) on the oxidative status of the liver and further liver values in rats.
In the first experiment, rats were exposed (n=6) or sham exposed (n=6) to microwaves (2.45 GHz). In the second experiment, rats were exposed to the radiofrequency field of a mobile phone (900 MHz) (remark EMF-Portal: in the second experiment, no information was given about number of animals and treatment of control animals).
周波数 | 2.45 GHz |
---|---|
タイプ |
|
特性 |
|
ばく露時間 | continuous for 2 hours/day for 35 days |
Modulation type | cf. additional information |
---|---|
Additional information |
50 Hz modulation frequency |
ばく露の発生源/構造 | |
---|---|
チャンバの詳細 | plexiglas cage with ventilation holes of 1 cm diameter |
ばく露装置の詳細 | exposure cage with animals was kept in an anechoic chamber; a microwave oven was used as exposure source connected to a 40 db attenuation and a horn antenna; animals were facing the horn antenna; temperature was maintained at 25-27°C |
Sham exposure | A sham exposure was conducted. |
周波数 | 900 MHz |
---|---|
タイプ |
|
ばく露時間 | intermittend for 2 hours/day for 35 days |
Modulation type | pulsed |
---|
ばく露の発生源/構造 |
|
---|---|
チャンバの詳細 | plexiglas cage with ventilation holes of 1 cm diameter in which rats were restricted (mobility 1-2 cm) during exposure |
ばく露装置の詳細 | exposure cage with animals was kept in an anechoic chamber; GSM mobile phones were kept on the top of the cage in such a configuration that there was preferential emissions towards the animals in the cage; every cage was attached with a seperate mobile phone; cell phone was in standby; calls lasted 1 min (no information given how many calls in the two hours); cell phones were in silent mode without vibration |
No parameters are specified for this exposure.
Rats exposed to microwaves (2.45 GHz) or to the radiofrequency field of a mobile phone (900 MHz) showed significantly decreased enzyme activities of the glutathione peroxidase and the superoxide dismutase when compared to the control, while the enzyme activity of the catalase and the lipid peroxidation were significantly increased.
Additionally, all liver values in the serum of exposed rats (microwave or mobile phone) were significantly increased in comparison to the control group.
The authors conclude that exposure to microwaves (2.45 GHz) or to the radiofrequency field of a mobile phone (900 MHz) could lead to oxidative stress in the liver and to increased liver values in rats.
このウェブサイトはクッキー(Cookies)を使って、最善のブラウジングエクスペリエンスを提供しています。あなたがこのウェブサイトを継続して使用することで、私たちがクッキーを使用することを許可することになります。