Es sollte untersucht werden, ob hoch-intensive gepulste magnetische Stimulation die Stärke und Dauer von Schmerz abschwächen kann.
10 adulte Testpersonen mit spezifischen Schmerzen (seit mindestens einem Jahr) wurden untersucht.
Exposition | Parameter |
---|---|
Exposition 1:
Modulationsart:
gepulst
Expositionsdauer:
6 Behandlungen je 10 min lang
|
|
Frequenz |
|
---|---|
Typ | |
Signalform | |
Expositionsdauer | 6 Behandlungen je 10 min lang |
Expositionsquelle |
|
---|---|
Aufbau | The inductor housing was applied to the areas of maximal pain. The plane of the coil was parallel to the body surface. Four control treatments were conducted by turning the stimulator on hence achieving the same noise but disconnecting the inductor from the stimulator. |
Zusatzinfo | The coil was easy to move hence the magnetic field was easily applied to the surface of the subjects. The subjects consisted of 5 males and 5 females who had been symptomatic and stationary for at least 1 year with their specific pain. |
Messgröße | Wert | Typ | Methode | Masse | Bemerkungen |
---|---|---|---|---|---|
magnetische Flussdichte | 1,17 T | Maximum | gemessen | - | an der Oberfläche der Spule |
Durch hoch-intensive gepulste magnetische Stimulation, die bei schmerzhaften Bereichen des menschlichen Körpers verwendet wurde, konnte eine signifikante Schmerz-Kontrolle erzielt werden. 50% der Testpersonen erfuhren eine anhaltende Schmerz-Linderung, wohingegen der Rest eine 8-72 Stunden dauernde konsistente Schmerz-Linderung hatten. Die Daten waren signifikant unterschiedlich zu den geblindeten Kontroll-Ergebnissen (Schein-Exposition).