Es sollten die Wirkungen von elektromagnetischen Feldern (GSM) auf kultivierte Schilddrüsen-Zellen untersucht werden.
Die Zellen wurden zwei Tage nach der Exposition untersucht.
Exposition | Parameter |
---|---|
Exposition 1:
800–900 MHz
Expositionsdauer:
kontinuierlich für 24, 48 oder 96 h
|
|
Expositionsquelle |
|
---|---|
Aufbau | two wire patch cells, each placed in a Faraday cage inside an CO2 incubator; absorbent material placed along the side walls of the cage; power cable inside the incubator shielded with an aluminum sheet; wire patch cell consisting of two square 15 cm x 15 cm plates, spaced 2.9 cm apart and using four metallic grounding contacts, located at each corner; coaxial cable placed in the center of the wire patch cell that connects the ground plate with the roof plate; E-field with dominant vertical component, polarized in z direction, orthogonal to the metallic plates; H-field with only longitudinal component; cells placed in eight 35 mm (diameter) Petri dishes which were placed in 50 mm diameter dishes in the wire patch cell |
Schein-Exposition | Eine Schein-Exposition wurde durchgeführt. |
Messgröße | Wert | Typ | Methode | Masse | Bemerkungen |
---|---|---|---|---|---|
Leistung | 0,5 W | - | - | - | - |
Die elektromagnetische Feld-Exposition für 24, 48 und 96 Stunden beeinflusste im Vergleich zu den Kontrollen nicht die Zelllebensfähigkeit, die cAMP-Produktion und die Iodid-Akkumulierung in FRTL-5-Zellen. Die Autoren kommen zu dem Schluss, dass elektromagnetische Felder unter diesen Bedingungen nicht auf die biochemischen Eigenschaften der FRTL-5-Zellen wirken.
Um diese Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu.