Ein Schwesterchromatid-Austausch-Test wurde genutzt, um potentielle mutagene Bioeffekte einer Mikrowellen-Befeldung (2450 MHz) auf Knochenmarks-Zellen der Maus zu untersuchen.
Exposition | Parameter |
---|---|
Exposition 1:
2,45 GHz
Modulationsart:
CW
Expositionsdauer:
8 h/Tag für 28 Tage.
|
|
Frequenz | 2,45 GHz |
---|---|
Typ | |
Signalform |
|
Expositionsdauer | 8 h/Tag für 28 Tage. |
Modulationsart | CW |
---|
Expositionsquelle | |
---|---|
Kammer | Environmental chamber lined with microwave absorber maintained at 22°C and 55 % humidity. |
Aufbau | Animals kept in 2.54 cm thick Styrofoam cages / 5 cm x 8 cm x 10 cm with the long axis of the cage and the animal parallel to electric field. |
Zusatzinfo | The cages were mounted in slots cut in a large Styrofoam sheet. The cages were located in a circular pattern and the animals were rotated around the circle of cages every 4 h. Control animals was kept in another enviromental chamber identical to the exposure chamber but the animals were not handled and remained in their home cages during the whole exposure period. |
Messgröße | Wert | Typ | Methode | Masse | Bemerkungen |
---|---|---|---|---|---|
SAR | 15,6 mW/g | Minimum | berechnet | Ganzkörper | 26,80 W/kg maximal Wert. |
Leistungsflussdichte | 200 W/m² | Mittelwert | gemessen | - | - |
Es wurde kein statistisch signifikanter Unterschied in der Schwesterchromatid-Austausch-Häufigkeit zwischen exponierten Tieren und Kontroll-Mäusen gefunden.