この研究は、パルス化超低周波磁界(ELF MF;ピーク値±200 μT)が、ばく露期間中にヒトの脳電図(EEG)に影響を与えるか否かを調べた。20人の被験者(男性10人、女性10人)は、カウンターバランスされた実験デザインで、それぞれ15分間の磁界ばく露セッションおよび擬似ばく露セッションの両方を受けた。分散分析の結果、アルファ活動は、磁界ばく露セッションの最初から5分後に、後頭部電極(O1、Oz、O2)[F(1,16)= 5.376、P < .01、η2 = 0.418]にわたって、有意に低下した;また、アルファ活動は、セッションの順番に関連することが見出された(ばく露ー擬似ばく露と擬似ばく露ーばく露を比較);アルファ活性のこの低下は、ばく露終了後の1分間で、擬似ばく露と比較して有意ではなくなった(P > .05)、と報告している。
The detailed summary of this article is not available in your language or incomplete. Would you like to see a complete translation of the summary? Then please contact us →
To study the effects of pulsed extremely low frequency magnetic fields on the human EEG during the exposure period.
In a previous study it was shown that after a 15 min exposure to a pulsed extremely low frequency magnetic field, with most power at frequencies between 0 and 500 Hz, human brain electrical activity is affected, specifically within the alpha waves frequency (8-13 Hz) (see publication 10628).
ばく露 | パラメータ |
---|---|
ばく露1:
Modulation type:
pulsed
ばく露時間:
15 min
|
|
周波数 |
|
---|---|
タイプ |
|
波形 |
|
ばく露時間 | 15 min |
Modulation type | pulsed |
---|---|
Additional information |
853 ms segment consisting of 18 pulses with each pulse having a maximum rise of 1 ms. Each pattern consised of a pulse segment followed by varying refractory periods of 110, 220, 330 ms plus a constant fourth period of 5000 ms after which another pulse segment (853 ms) was delivered. This pattern was repeated for 15 min. |
ばく露の発生源/構造 | |
---|---|
ばく露装置の詳細 | Subjects were seated in the exposure system consisting of three orthogonal square coils with only the vertical coil pair powered. |
Sham exposure | A sham exposure was conducted. |
測定量 | 値 | 種別 | Method | Mass | 備考 |
---|---|---|---|---|---|
磁束密度 | 200 µT | peak | 指定なし | - | - |
Occipital alpha waves activity (8-13 Hz) decreased during exposure to a pulsed extremely low frequency magnetic field compared to sham exposure. This effect was revealed after the first 5 min of a 15 min irradiation and was dependent on the magnetic field/sham order of exposure. This decrease was no longer significant in the first minute post-exposure, compared to sham exposure.
(Discrepancies between the current results and the data of the previous study suggest that the EEG changes may be sensitive to the characteristics of the magnetic field pulse train).