この研究は、麻酔したSprague-Dawleyラット(n = 10)に、Sandia超広帯域(UWB)パルス発生器が生成するパルスを、異なるパルス繰り返し周波数(50、500、1000 パルス/秒)でばく露し、心臓血管系への影響を調べた。パルスパラメータは、3つのパルス繰り返し周波数での平均で、立ち上がり時間 174-218 ps、電界強度ピーク値 87-104kV / m、パルス幅 0.97~0.99 nsであった。結果として、 50、500、1000 パルス/秒での2分間のばく露中およびばく露終了後の2分間、30秒毎に測定された心拍数または平均動脈血圧に有意な変化はなかった、と報告している。
The detailed summary of this article is not available in your language or incomplete. Would you like to see a complete translation of the summary? Then please contact us →
To report heart rate and mean arterial blood pressure during exposure of anesthetized rats to ultra-wideband pulses.
ばく露 | パラメータ |
---|---|
ばく露1:
0–4 GHz
Modulation type:
pulsed
ばく露時間:
continuous for 2 min
|
|
ばく露2:
0–4 GHz
Modulation type:
pulsed
ばく露時間:
continuous for 2 min
|
|
ばく露3:
0–4 GHz
Modulation type:
pulsed
ばく露時間:
continuous for 2 min
|
The order of exposures to all four conditions (including sham) was randomised for each animal.
周波数 | 0–4 GHz |
---|---|
タイプ |
|
波形 |
|
特性 |
|
ばく露時間 | continuous for 2 min |
Modulation type | pulsed |
---|---|
Pulse width | 0.97 ns |
Rise time | 177 ps |
Repetition frequency | 50 Hz |
Additional information |
rise time SD ± 21 ps |
ばく露の発生源/構造 |
|
---|---|
Distance between exposed object and exposure source | 77 cm |
チャンバの詳細 | The tapered outer or ground conductor had a square cross-section of 11.0-71.7 cm on a side in the usable region. The center or septum conductor was 7.8-56.3 cm wide and 2.6 cm thick. A volume of 20 x 20 x 40 cm was available on each side. |
ばく露装置の詳細 | The anaesthetised animal was positioned on a Styrofoam block on the bottom wall and centered between the side walls of the GTEM cell with the head towards the source and the thorax 77 cm from the source end. |
Sham exposure | A sham exposure was conducted. |
周波数 | 0–4 GHz |
---|---|
タイプ |
|
波形 |
|
特性 |
|
ばく露時間 | continuous for 2 min |
Modulation type | pulsed |
---|---|
Pulse width | 0.97 ns |
Rise time | 174 ps |
Repetition frequency | 500 Hz |
Additional information |
rise time SD ± 19 ps |
ばく露の発生源/構造 |
|
---|
周波数 | 0–4 GHz |
---|---|
タイプ |
|
波形 |
|
特性 |
|
ばく露時間 | continuous for 2 min |
Modulation type | pulsed |
---|---|
Pulse width | 0.99 ns |
Rise time | 218 ps |
Repetition frequency | 1,000 Hz |
Additional information |
rise time SD ± 70 ps |
ばく露の発生源/構造 |
|
---|
The results suggest that acute ultra-wideband whole-body exposure under these conditions does not have an immediate detrimental effect on these cardiovascular system variables in anesthetized rats.