この研究は、携帯電話の低レベル無線周波(RF)電磁界が神経系に影響を与えるか否かを検出する効果的なツールとして、RFばく露下でニューラルネットワーク(神経細胞を培養して作成した神経回路網)の自発的な電気的活動を観察する実験装置を開発し、予備的実験の結果を報告している。開発した装置は、TEMセルを用いて、ニューラルネットワークにGSM1800信号をばく露(SAR:3.2W/kg)し、同時に、マイクロ電極アレイを用いて、ばく露下でのニューラルネットワークの電気的活動の記録、ならびに細胞外スパイクおよびバースト信号の検出を行う。16個の培養ニューラルネットワークでの予備的実験の結果、3分間のRFばく露により、発火頻度およびバースト発火頻度に回復可能な30%の減少が見られた、と報告している。
The detailed summary of this article is not available in your language or incomplete. Would you like to see a complete translation of the summary? Then please contact us →
To test the feasibility of studying the electrical activity of neuronal networks under radio frequency-exposure at 1800 MHz in vitro.
In many studies, indications of an effect of radiofrequency electromagnetic fields on the human EEG have been found (for example Schmid et al., 2012; Croft et al., 2010). To clarify the mechanisms underlying these potential effects on the brain, the research group has developed an experimental setup for the simultaneous exposure of neuronal networks and monitoring the electrical activity.
Recordings were made 3 minutes before, three minutes during and three minutes after the exposure period with 16 independent cultures.
周波数 | 1,800 MHz |
---|---|
タイプ |
|
ばく露時間 | continuous for 3 minutes |
Modulation type | pulsed |
---|---|
Additional information |
GSM signal |
ばく露の発生源/構造 | |
---|---|
チャンバの詳細 | 6 mm-high glass cylinder, sealed with biocompatible silicone was used as a culture chamber and put on a microelectrode array |
ばく露装置の詳細 | microelectrode array (60 platinum electrodes, 200 µm spaced with 40 µm diameter tips) with culture chamber was placed inside the TEM cell in an incubator (37°C, 5 % CO2) |
Sham exposure | A sham exposure was conducted. |
No differences in the electrical activity were observed before and after the exposure or sham exposure. However, during exposure, the firing rate and the bursting rate were significantly decreased (around 30 %) in comparison to sham exposure.
The authors demonstrated the feasibility of studying the electrical activity of neuronal networks under radio frequency-exposure at 1800 MHz in vitro.