この研究は、ケタミンで麻酔したSprague-Dawleyラットを、EおよびH方向に向けて、遠方界の2.45GHz連続波電磁界放射(RFR:60mW / cm 2)のばく露を与えた。全身平均SARは約14 W / kgであった。両方向での断続的なばく露を同じ動物で行って、反復的に結腸温度を38.5℃から39.5℃まで上昇させた。鼓膜、皮下(RFR源に近い側および遠い側)、結腸温度、ECG、動脈圧および呼吸数を連続的に記録した。その結果、動物内の熱分布のパターンおよび生理学的応答は、EおよびH方向でのばく露によって有意に異なっていた;心拍数および血圧は、ばく露中に有意に増加し、ばく露が中止されるとベースラインレベルに戻った;増加はH方向よりもE方向において有意に大きかった;呼吸数は、H方向では有意に増加したが、E方向では増加しなかった、と報告している。
The detailed summary of this article is not available in your language or incomplete. Would you like to see a complete translation of the summary? Then please contact us →
To compare the effects of acute exposure to 2.45 GHz radiofrequency irradiation in E-orientation (long axis of body parallel to electric field) and H-orientation (long axis of body parallel to magnetic field) upon the patterns of heat distribution, the overall heating and cooling responses, and changes in cardiovascular and respiratory function in anesthetized rats.
*The exposure was discontinued when the colonic temperature increased to 39.5°C and it was initiated again when the temperature returned to 38.5°C. This procedure was continued for 3 cycles
周波数 | 2.45 GHz |
---|---|
タイプ |
|
特性 |
|
偏波 |
|
ばく露時間 | intermittent* |
Additional information | Animals were exposed in E orientation (long axis of their body parallel electric field) |
Modulation type | CW |
---|
ばく露の発生源/構造 | |
---|---|
Distance between exposed object and exposure source | 0.0015 m |
チャンバの詳細 | Eccosorb RF-shielded anechoic chamber |
ばく露装置の詳細 | Rats placed on a holder |
Additional information | The rise time and the recovery time were 8.6 ± 0.4 and 16.6 ± 1.3 min respectively The holder consisted of seven 0.5 cm (O.D) Plexiglas rods mounted in a semicircular pattern on 4 cm x 6 cm Plexiglas plates (0.5 cm thick) |
周波数 | 2.45 GHz |
---|---|
タイプ |
|
特性 |
|
偏波 |
|
ばく露時間 | intermittent* |
Additional information | Animals exposed in H orientation (magnetic field parallel to the long axis of the animal) |
Modulation type | CW |
---|
ばく露の発生源/構造 | |
---|---|
Distance between exposed object and exposure source | 0.0015 m |
チャンバの詳細 | Eccosorb RF-shielded anechoic chamber |
ばく露装置の詳細 | Rats placed on a holder |
Additional information | The rise time and the recovery time were 8.0 ± 0.2 and 15.2 ± 1.1 min respectively The holder consisted of seven 0.5 cm (O.D) Plexiglas rods mounted in a semicircular pattern on 4 cm x 6 cm Plexiglas plates (0.5 cm thick) |
The pattern of heat distribution within the rat and the physiological responses were significantly different between E- and H-orientation irradiation. Exposure in E-orientation resulted in greater peripheral and tympanic heating, while exposure in H-orientation resulted in greater body core heating.
Heart rate and blood pressure increased significantly during exposure and returned to baseline levels when irradiation was discontinued; the increases were significantly greater in E- than in H-orientation. Respiratory rate increased significantly during exposure in H-, but not in E-orientation.
The physiological responses could have been influenced by the different levels or rates of subcutaneous and tympanic heating, or the differential between body core and peripheral heating during E- and H-orientation exposure.