Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Sanie-Jahromi F et al. | 2016 | intact cell/cell culture, MCF-7 (human breast cancer cell line) and SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz, co-exposure | 0.25–0.5 mT |
Mahmoudinasab H et al. | 2016 | intact cell/cell culture, MCF-7 cells (human breast cancer cell line) | magnetic field, 50/60 Hz | 0.25–0.5 mT |
Mahmoudinasab H et al. | 2016 | intact cell/cell culture, MCF-7 cells (human breast cancer cell line) | magnetic field, 50/60 Hz | 0.25–0.5 mT |
Mansoury F et al. | 2021 | intact cell/cell culture | magnetic field, low frequency, 50/60 Hz | 0.25–2 mT |
Kitaoka K et al. | 2016 | intact cell/cell culture, mouse adrenal cortex-derived cells (Y-1) and human adrenal cortex-derived cells (H295R) | magnetic field, 50/60 Hz | 0.25–3 mT |
Malagoli D et al. | 2004 | invertebrate, mussel/<i>Mytilus galloprovincialis</i>, whole body | magnetic field, 50/60 Hz | 300–600 µT |
Shin EJ et al. | 2011 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz, co-exposure | 0.3–2.4 mT |
Goodman R et al. | 1989 | intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells) | magnetic field, low frequency, signals/pulses, 50/60 Hz | 0.38–3.5 mT |
Goodman R et al. | 1988 | isolated organ, salivary glands from <i>Sciara coprophila</i> (Insecta, Diptera) | magnetic field, signals/pulses, 50/60 Hz, therapeutic/medical device | 0.38–3.5 mT |
Li H et al. | 2005 | intact cell/cell culture, MCF-7 (human breast cancer cell line) | magnetic field, 50/60 Hz | 0.4 mT |
Chen G et al. | 2012 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/S288C | GSM, mobile communications, RF field, PW pulsed wave, magnetic field, low frequency, 50/60 Hz | 0.4 mT |
Qiu L et al. | 2019 | intact cell/cell culture, human amniotic (FL) cells | 50/60 Hz, magnetic field | 0.4 mT |
Santini MT et al. | 2003 | intact cell/cell culture, human osteosarcoma cell lines (MG-63 and Saos-2) | magnetic field, 50/60 Hz | 500 µT |
Somosy Z et al. | 2004 | intact cell/cell culture, Madin-Darby canine kidney (MDCK) cells | magnetic field, 50/60 Hz | 500 µT |
Zhong C et al. | 2012 | intact cell/cell culture, mesenchymal bone marrow stem cells of mice (rat?, remark EMF-Portal: contradictory information) | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Hemmati M et al. | 2014 | animal, mouse/Balb/c (embryo), whole body: <i>in utero</i> | magnetic field, 50/60 Hz | 0.5 mT |
Li C et al. | 2014 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 0.5 mT |
Rezaie-Tavirani M et al. | 2017 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz | 0.5–1 mT |
Ma Q et al. | 2014 | intact cell/cell culture, embryonic neural stem cells (mouse/BALB/c) | magnetic field, 50/60 Hz | 0.5–2 mT |
Xie YF et al. | 2016 | intact cell/cell culture, rat calvarial osteoblasts | magnetic field, signals/pulses, 50/60 Hz | 0.6 mT |
Olivares-Banuelos T et al. | 2004 | intact cell/cell culture, chromaffin cells (from neonatal Wistar rats) | magnetic field, 50/60 Hz | 700 µT |
Wu RY et al. | 2000 | intact cell/cell culture, Daudi (Burkitt's lymphoma cell line) cells | magnetic field, 50/60 Hz | 800 µT |
Ventura C et al. | 2005 | intact cell/cell culture, GTR1 cells (derivative of R1 embryonic stem cells) | magnetic field, 50/60 Hz | 0.8 mT |
Zhou J et al. | 2011 | intact cell/cell culture, osteoblasts | magnetic field, low frequency, 50/60 Hz | 0.9–4.8 mT |
Pieroni L et al. | 1998 | intact cell/cell culture, virus/bacteriophages, murine B lymphocytes and T lymphocytes infected with a murine retrovirus (Mo-MLV) | magnetic field, 50/60 Hz | 1 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.