Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Zuo H et al. | 2018 | - | magnetic field, 50/60 Hz, low frequency | - |
Sun H et al. | 2010 | animal, chicken embryos (eggs) | magnetic field, 50/60 Hz | 2 mT |
Che Y et al. | 2007 | animal, chicken/Lohmann brown, whole body | magnetic field, 50/60 Hz | 1 mT |
Kavaliers M et al. | 1996 | animal, deer mouse, whole body | magnetic field, 50/60 Hz | 100 µT |
Wolpaw JR et al. | 1989 | animal, monkey/southern pig-tailed macaque (<i>Macaca nemestrina</i>), whole body | electric field, magnetic field, 50/60 Hz | 10–90 µT |
de Lorge J et al. | 1977 | animal, monkey/squirrel monkey (<i>Saimiri sciureus</i>) and rhesus monkey (<i>Macaca mulatta</i>), whole body | electric field, magnetic field, 50/60 Hz | 3–10 mT |
Orr JL et al. | 1995 | animal, monkey/yellow baboon (<i>Papio cynocephalus</i>), whole body | electric field, magnetic field, 50/60 Hz | 50–100 µT |
Foroozandeh E et al. | 2013 | animal, mouse, whole body | magnetic field, 50/60 Hz | 8 mT |
Hu Y et al. | 2016 | animal, mouse/3xTg and 129/C57BL/6, whole body | magnetic field, 50/60 Hz | 500 µT |
Liebl MP et al. | 2015 | animal, mouse/APP23, SOD1<sup>G85R</sup>, SOD1<sup>G93A</sup>, SOD1<sup>WT</sup>, wild type, whole body | magnetic field, 50/60 Hz | 1 mT |
Alsaeed I et al. | 2014 | animal, mouse/BALB/c, whole body | magnetic field, 50/60 Hz | 1 mT |
Sakhaie MH et al. | 2017 | animal, mouse/BALB/c, whole body | magnetic field, low frequency, 50/60 Hz | 1 mT |
Urnukhsaikhan E et al. | 2017 | animal, mouse/C57B6, whole body | magnetic field, signals/pulses, 50/60 Hz | 10 mT |
Cui Y et al. | 2012 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz | 0.1–1 mT |
Sienkiewicz ZJ et al. | 1998 | animal, mouse/C57BL/6J, whole body | magnetic field, 50/60 Hz | 750 µT |
Sienkiewicz ZJ et al. | 2001 | animal, mouse/C57BL/6J, whole body | magnetic field, 50/60 Hz | 750 µT |
Jeong JH et al. | 2000 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz, co-exposure | 2 mT |
Fu Y et al. | 2008 | animal, mouse/ICR, whole body | magnetic field, low frequency, 50/60 Hz | 0.6–2 mT |
Duan Y et al. | 2013 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 8 mT |
Zhao QR et al. | 2015 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 0.4–1 mT |
Zhang Y et al. | 2017 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz, static magnetic field | 1 mT |
Gao QH et al. | 2017 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz, co-exposure | 0.2 mT |
Deng Y et al. | 2013 | animal, mouse/Kunming (SPF), whole body | magnetic field, 50/60 Hz, co-exposure | 2 mT |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Wang X et al. | 2013 | animal, mouse/albino Kunming, whole body | magnetic field, low frequency, 50/60 Hz | 2 mT |
Gao Q et al. | 2021 | animal, rat/Sprague Dawley (focal ischemia model), whole body | magnetic field, 50/60 Hz | 1 mT |
Lai J et al. | 2016 | animal, rat/Sprague Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Aydemir S et al. | 2016 | animal, rat/Sprague Dawley, whole body | magnetic field, 50/60 Hz | 0.21–2.7 µT |
Lai H | 1996 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 750 µT |
Lai H et al. | 1998 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 1 mT |
Liu T et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 2 mT |
He LH et al. | 2011 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 2 mT |
Zhang C et al. | 2013 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 100 µT |
Li Y et al. | 2014 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Li C et al. | 2014 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 0.5 mT |
Zhang Y et al. | 2015 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Liu Z et al. | 2019 | animal, rat/Sprague-Dawley, whole body | 50/60 Hz, magnetic field | 30–500 µT |
Faraji N et al. | 2021 | animal, rat/Wistar | magnetic field, low frequency, 50/60 Hz | - |
Sofiabadi M et al. | 2018 | animal, rat/Wistar (<i>in utero</i>), whole body | magnetic field, 50/60 Hz, co-exposure | - |
Chittora R et al. | 2024 | animal, rat/Wistar (Alzheimer's disease model) | magnetic field, 50/60 Hz | - |
Bose S et al. | 2023 | animal, rat/Wistar (Parkinson's disease model) | magnetic field, 50/60 Hz | - |
Rakesh RM et al. | 2008 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 17.9 µT |
Fournier NM et al. | 2012 | animal, rat/Wistar albino, whole body: <i>in utero</i> | magnetic field, low frequency, signals/pulses, 50/60 Hz | 20–1,200 nT |
Jadidi M et al. | 2007 | animal, rat/Wistar, partial body: head | magnetic field, 50/60 Hz | 2–8 mT |
Vazquez-Garcia M et al. | 2004 | animal, rat/Wistar, whole body | magnetic field, low frequency, 50/60 Hz | 1 mT |
Reyes-Guerrero G et al. | 2006 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 1 mT |
Das S et al. | 2012 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure, therapeutic/medical device | 17.96 µT |
Liu X et al. | 2015 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 380–420 µT |
Rostami A et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 4 mT |
Akbarnejad Z et al. | 2018 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 10 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.