Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Vianale G et al. | 2008 | intact cell/cell culture, HaCaT cells (human keratinocytes) | magnetic field, 50/60 Hz | 1 mT |
Cellini L et al. | 2008 | bacterium, <i>Escherichia coli</i>/ATCC 700926 | magnetic field, low frequency, 50/60 Hz | 0.1–1 mT |
Sakurai T et al. | 2008 | intact cell/cell culture, HIT-T15 cells (hamster-derived insulin-secreting cell line) | magnetic field, low frequency, 50/60 Hz | 5 mT |
Del Giudice E et al. | 2007 | intact cell/cell culture, human neuroglioma cell line (H4; cells transfected with the human amyloid precursor protein (APP)) | magnetic field, 50/60 Hz | 3.1 mT |
Novak J et al. | 2007 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>) | magnetic field, 50/60 Hz | 5.2–10 mT |
Fojt L et al. | 2007 | bacterium, <i>Paracoccus denitrificans</i>/CCM 982 | magnetic field, 50/60 Hz | 10 mT |
Shang GM et al. | 2004 | intact cell/cell culture, <i>Taxus chinensis</i> var. <i>mairei</i> | static magnetic field, magnetic field, 50/60 Hz | - |
Del Re B et al. | 2004 | bacterium, <i>Escherichia coli</i>/Lac Z<sup>-</sup> strain (transformed with a plasmid containing a Tn10 derivative element expressing beta-galactosidase only after transposition)) | magnetic field, low frequency, 50/60 Hz | 0.05–1 mT |
Fojt L et al. | 2004 | bacterium, <i>Escherichia coli</i>, <i>Leclercia adecarboxylata</i>, <i>Staphylococcus aureus</i> | magnetic field, low frequency, 50/60 Hz | 2.7–10 mT |
Verheyen GR et al. | 2003 | intact cell/cell culture, human lymphocytes | magnetic field, 50/60 Hz, co-exposure | 80–800 µT |
Strasak L et al. | 2002 | bacterium, <i>Escherichia coli</i> | magnetic field, 50/60 Hz | 2.7–10 mT |
Markkanen A et al. | 2001 | yeast (<i>Saccharomyces cerevisiae</i>/SEy2101a) | magnetic field, 50/60 Hz, co-exposure | 120 µT |
Yaguchi H et al. | 2000 | intact cell/cell culture, mouse m5S cells | magnetic field, 50/60 Hz, power transmission line, co-exposure | 5–400 mT |
Miyakoshi J et al. | 2000 | intact cell/cell culture, MO54 cells (derived from a human malignant glioma) | magnetic field, 50/60 Hz, co-exposure | 5–400 mT |
Ansari RM et al. | 2000 | intact cell/cell culture, human-hamster hybrid cells | magnetic field, 50/60 Hz, co-exposure | 100 µT |
Loberg LI et al. | 2000 | intact cell/cell culture, MCF-7, ZR-75-1, T-47D, and MDA-MB-231 (breast cancer cell line) and normal human breast epithalial cells | magnetic field, 50/60 Hz | 1 mT |
Ramstad S et al. | 2000 | bacterium, <i>Propionibacterium acnes</i> | electric field, magnetic field, 50/60 Hz | 200 µT |
Gamble SC et al. | 1999 | intact cell/cell culture, SHD (syrian hamster dermal) cells | magnetic field, 50/60 Hz, power transmission line, co-exposure | 10–1,000 µT |
Pieroni L et al. | 1998 | intact cell/cell culture, virus/bacteriophages, murine B lymphocytes and T lymphocytes infected with a murine retrovirus (Mo-MLV) | magnetic field, 50/60 Hz | 1 mT |
Reipert BM et al. | 1997 | intact cell/cell culture, FDCP-mix(A4) cell line (mouse bone marrow cells) | magnetic field, static magnetic field, 50/60 Hz, shielding/field deprivation | 0.2 µT–2 mT |
Miyakoshi J et al. | 1997 | intact cell/cell culture, MeWo cells (malignant melanoma cells) | magnetic field, 50/60 Hz, also other exposures without EMF | 400–500 mT |
Schimmelpfeng J | 1997 | intact cell/cell culture, HL-60 (human promyelocytic leukemia cells) | magnetic field, 50/60 Hz, co-exposure | 2 mT |
Eremenko T et al. | 1997 | intact cell/cell culture, Friend erythroleukemia cell line (clone 745 A) | magnetic field, geomagnetic field, 50/60 Hz, shielding/field deprivation | 0.0025 nT–70 µT |
Schimmelpfeng J et al. | 1997 | intact cell/cell culture, SV40-swiss-3T3 cells (mouse fibroblast cell line) and HL-60 cells (human acute myeloid leukaemia cell line) | magnetic field, 50/60 Hz | 2 mT |
Kula B et al. | 1996 | intact cell/cell culture, fibroblasts | magnetic field, static magnetic field, low frequency, 50/60 Hz | 20–490 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.