Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Ardeshirylajimi A et al. | 2015 | intact cell/cell culture, human induced pluripotent stem cells | magnetic field, signals/pulses, 50/60 Hz | 1.5 mT |
Martinez MA et al. | 2015 | intact cell/cell culture, human mesenchymal stem cells derived from fat tissue | magnetic field, 50/60 Hz | 100 µT |
Lee HN et al. | 2015 | intact cell/cell culture, bone marrow-derived mesenchymal stem cells (BM-MSCs) | magnetic field, 50/60 Hz | - |
Cheng Y et al. | 2015 | intact cell/cell culture, neural progenitor cells from the brain of mice embryos and ischemic brain of adult mice (C57BL/6J) | magnetic field, 50/60 Hz | 0.4 mT |
Fan W et al. | 2015 | intact cell/cell culture, mesenchymal bone marrow stem cells (from SD rats) and mesenchymal stem cells (from mouse) | magnetic field, 50/60 Hz | 1 mT |
Ledda M et al. | 2015 | intact cell/cell culture, human mesenchymal stem cells | magnetic field, static magnetic field, 50/60 Hz, co-exposure | 66 µT–1 mT |
Wang Q et al. | 2014 | - | magnetic field, signals/pulses, 50/60 Hz, co-exposure, therapeutic/medical device | - |
Baek S et al. | 2014 | intact cell/cell culture, mouse fibroblasts, transfected with lentivirus with OKSM gene constructs from HEK293 cells | magnetic field, low frequency, 50/60 Hz, shielding/field deprivation | 1 mT |
Jung IS et al. | 2014 | intact cell/cell culture, PC-12 cells (pheochromocytoma cell line from rat adrenal gland) | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Choi YK et al. | 2014 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs) | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Bishi DK et al. | 2014 | intact cell/cell culture, human mesenchymal stem cells | magnetic field, 50/60 Hz | 60 mT |
Seong Y et al. | 2014 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs), mouse neural stem cells, animal, mouse, whole body | magnetic field, 50/60 Hz | 1–2 mT |
Yu JZ et al. | 2014 | intact cell/cell culture, mesenchymal bone marrow stem cells (rat) and osteoblasts (rat) | magnetic field, 50/60 Hz | 1 mT |
Ma Q et al. | 2014 | intact cell/cell culture, embryonic neural stem cells (mouse/BALB/c) | magnetic field, 50/60 Hz | 0.5–2 mT |
Hilz FM et al. | 2014 | intact cell/cell culture, primary articular chondrocytes (from calf fetlock joints) | magnetic field, 50/60 Hz, co-exposure | 1–3 mT |
Bai WF et al. | 2013 | intact cell/cell culture, bone mesenchymal stroma cells (rat) | magnetic field, 50/60 Hz | 5 mT |
Cid MA et al. | 2012 | intact cell/cell culture, Hep G2 cells (hepatic transformed cell line) | magnetic field, 50/60 Hz, co-exposure | 10 µT |
Luo F et al. | 2012 | intact cell/cell culture, mesenchymal bone marrow stem cells | magnetic field, low frequency, signals/pulses, 50/60 Hz, electrotherapy | 1.1 mT |
Delle Monache S et al. | 2008 | intact cell/cell culture, human vein endothelial cells (HUVEC) | magnetic field, low frequency, 50/60 Hz | 1 mT |
Piacentini R et al. | 2008 | intact cell/cell culture, neural stem cells/progenitor cells from brain cortices of postnatal day 0 CD-1 mice | magnetic field, low frequency, 50/60 Hz | 1 mT |
Pozzi D et al. | 2007 | intact cell/cell culture, LAN-5 cells (human neuroblastoma cell line) | magnetic field, 50/60 Hz | 2 mT |
Sul AR et al. | 2006 | intact cell/cell culture, hFOB 1.19 (human fetal osteoblasts), T/G HA-VSMC (human aortic vascular smooth muscle cells), RPMI 7666 (human B lymphoblasts) and HCN-2 (human cortical neuronal cells) | magnetic field, 50/60 Hz | 2 mT |
Lisi A et al. | 2006 | intact cell/cell culture, AtT20 D16V cells (pituitary corticotrope-derived cells) | magnetic field, 50/60 Hz | 2 mT |
Amaroli A et al. | 2006 | intact cell/cell culture, <i>Dictyostelium discoideum</i> (amoeba) | magnetic field, 50/60 Hz | 200 µT |
Ventura C et al. | 2005 | intact cell/cell culture, GTR1 cells (derivative of R1 embryonic stem cells) | magnetic field, 50/60 Hz | 0.8 mT |
Wu H et al. | 2005 | intact cell/cell culture, mouse mesenchymal stem cells | magnetic field, low frequency, signals/pulses, 50/60 Hz | 2 mT |
Lisi A et al. | 2005 | intact cell/cell culture, rat cerebellar granule cells | magnetic field, 50/60 Hz | 1 mT |
Zhang Y et al. | 2005 | intact cell/cell culture, PC-12 cells (pheochromocytoma cell line from rat adrenal gland) | magnetic field, signals/pulses, 50/60 Hz | 100 µT–1.36 mT |
Schimmelpfeng J et al. | 2005 | intact cell/cell culture, PC-12 cells/rat | magnetic field, 50/60 Hz | 100 µT |
Fan W et al. | 2004 | intact cell/cell culture, PC-12 cells | magnetic field, signals/pulses, 50/60 Hz | 230 µT–1.32 mT |
Olivares-Banuelos T et al. | 2004 | intact cell/cell culture, chromaffin cells (from neonatal Wistar rats) | magnetic field, 50/60 Hz | 700 µT |
Manni V et al. | 2004 | intact cell/cell culture, human oral keratinocytes | magnetic field, 50/60 Hz | 2 mT |
Pirozzoli MC et al. | 2003 | intact cell/cell culture, LAN-5 (human neuroblastoma cells) | magnetic field, 50/60 Hz | 1 mT |
Chen G et al. | 2000 | intact cell/cell culture, Friend erythroleukemia cell line | magnetic field, 50/60 Hz | 0.1–1 mT |
Aaron RK et al. | 1999 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, power transmission line | 0.01–0.1 mT |
Morgado-Valle C et al. | 1998 | intact cell/cell culture, chromaffin cells (from postnatal Wistar rat adrenal medulla) | magnetic field, 50/60 Hz, co-exposure | 700 µT |
Ubeda A et al. | 1996 | intact cell/cell culture, PC-12D cells (subline of the PC-12 cell line, derived from pheochromocytoma cells from the rat adrenal medulla) | magnetic field, 50/60 Hz, co-exposure | 4 µT |
Cadossi R | 1990 | intact cell/cell culture, human peripheral blood lymphocytes (from normal donors, donors with chronic lymphocytic leukemia, and elderly donors), animal, C3H mice, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz, co-exposure | - |