Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Persson BRR et al. | 1997 | animal, rat/Fischer 344 | permeability of blood-brain barrier | 915 MHz | 8 mW/kg–8.3 W/kg | continuous for 2 min to 960 min | GSM, TDMA, mobile communications, microwaves |
Schirmacher A et al. | 2000 | model of blood-brain barrier (consisting of astrocytes and capillary endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.8 GHz | 0.3–0.46 W/kg | continuous for 4 days | GSM, mobile communications |
Finnie JW et al. | 2001 | animal, mouse/C57BL/6NTac, whole body | blood-brain barrier permeability | 898.4 MHz | 4 W/kg | continuous for 60 min | GSM, mobile communications |
Finnie JW et al. | 2006 | animal, mouse/BALB/c, whole body | blood-brain barrier permeability | 900 MHz | 4 W/kg | repeated daily exposure for 60 min/day from day 1 to day 19 of gestation | GSM, mobile communications |
Fritze K et al. | 1997 | animal, rat/Wistar, partial body: head | permeability of the blood-brain barrier | 900 MHz | 0.3–7.5 W/kg | continuous for 4 h | GSM, mobile communications, microwaves |
Salford LG et al. | 1994 | animal, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.016–5 W/kg | continuous for 2 h | GSM, mobile communications, microwaves |
Finnie JW et al. | 2002 | animal, mouse/C57BL/6NTac, whole body | blood-brain barrier permeability | 900 MHz | 0.25–4 W/kg | repeated daily exposure for 60 min/day, 5 days/week for 2 years | GSM, mobile communications, microwaves |
Salford LG et al. | 2003 | animal, rat/Fischer 344, whole body | permeability of blood-brain-barrier | 915 MHz | 2–200 mW/kg | continuous for 2 hours | GSM, mobile communications, microwaves |
Franke H et al. | 2005 | intact cell/cell culture, model of blood-brain barrier (consisting of astrocytes and capillary endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.8 GHz | 0.3–0.46 W/kg | continuous for up to 5 days | GSM, mobile communications, microwaves |
Persson BR et al. | 1992 | animal, rat/Sprague-Dawley & Fischer 344, whole body | permeability of the blood-brain barrier | 915 MHz | - | continuous for 2 h | GSM, mobile communications, microwaves, magnetic field, static magnetic field |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.