Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
de Gannes FP et al. | 2009 | animal, rat/Fischer 344, partial body: head | permeability of blood-brain barrier and neuron degeneration | 900 MHz | 0.14–2 W/kg | continuous for 2 hr | mobile phone, digital mobile phone, GSM, mobile communications |
Kuribayashi M et al. | 2005 | animal, rat/Fischer 344, partial body: head (nose) | blood-brain barrier | 1,439 MHz | 0.29–6 W/kg | repeated daily exposure, 90 min/day, 6 days/week, for 1 or 2 weeks | PDC, TDMA, mobile communications |
Salford LG et al. | 2003 | animal, rat/Fischer 344, whole body | permeability of blood-brain-barrier | 915 MHz | 2–200 mW/kg | continuous for 2 hours | GSM, mobile communications, microwaves |
Grafstrom G et al. | 2008 | animal, rat/Fischer 344, whole body | neuronal damage, blood-brain barrier permeability and effects on ageing process and memory | 900 MHz | 0.6–60 mW/kg | 2 hr/week for 55 weeks | mobile phone, digital mobile phone, GSM, mobile communications |
Eberhardt JL et al. | 2008 | animal, rat/Fischer 344, whole body | blood-brain barrier permeability and nerve cell damage | 900 MHz | 0.12–120 mW/kg | continuous for 2 h | mobile phone, GSM, mobile communications |
Nittby H et al. | 2009 | animal, rat/Fischer 344, whole body | blood-brain barrier permeability and neuronal damage | 915 MHz | 0.12–120 mW/kg | continuous for 2 hr | mobile phone, GSM, mobile communications, microwaves |
Masuda H et al. | 2009 | animal, rat/Fischer 344, whole body | permeability of blood-brain barrier | 915 MHz | 0.02–2 W/kg | continuous for 2 h | mobile communications, digital mobile phone, GSM |
Nittby H et al. | 2011 | animal, rat/Fischer 344, whole body | blood-brain barrier permeability | 50 Hz | 0.37–0.44 mW/kg | continuous for 2 h | digital mobile phone, GSM, mobile communications, RF, PW pulsed wave, magnetic field, low frequency, 50/60 Hz |
Persson BRR et al. | 2005 | animal, rat/Fischer 344, whole body | - | 915 MHz | 0.2–200 mW/kg | not specified in the article | digital mobile phone, GSM, mobile communications, microwaves, CW continuous wave, PW pulsed wave |
Masuda H et al. | 2015 | animal, rat/Sprague Dawley | - | 1,457 MHz | - | - | mobile communications, PDC, microwaves |