Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
De Iuliis GN et al. | 2009 | intact cell/cell culture, human spermatozoa | sperm motility, sperm vitality, sperm density, DNA damage and production of reactive oxygen species | 1.8 GHz | 0.4–27.5 W/kg | continuous for 16 hr | mobile phone, mobile communications |
Stagg RB et al. | 2001 | animal, rat/Fischer 344, partial body: head | stress response | 1.6 GHz | 0.6–5 W/kg | continuous for 2 h | digital mobile phone, IRIDIUM, mobile communications, microwaves |
Lixia S et al. | 2006 | intact cell/cell culture, SRA01/04-hLEC (human eye lens epithelial cells) | comet assay, stress response/gene expression, cell proliferation | 1.8 GHz | 1–3 W/kg | continuous for 2 h | digital mobile phone, GSM, TDMA, mobile communications |
Sanchez S et al. | 2008 | animal, rat/hairless, partial body: right part of the back | Heat shock protein expression | 900 MHz | 2.4–5.8 W/kg | continuous for 2 h | GSM, mobile communications |
Khalil AM et al. | 2012 | animal, rat/Sprague-Dawley, whole body | DNA damage/oxidative stress (urinary level of 8-hydroxy-2-deoxyguanosine) | 1,800 MHz | - | continuous for 2 h | mobile phone, GSM, mobile communications |
Hong MN et al. | 2012 | intact cell/cell culture, MCF10 A cells (human breast epithelial cells) | oxidative stress | 837 MHz | 2–4 W/kg | continuous for 2 h | mobile phone, CDMA, W-CDMA, mobile communications |
Khirazova EE et al. | 2012 | animal, white rat, whole body | behavior in open field test, antioxidant defense system | 905 MHz | 1.67 W/kg | continuous for 2 h | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Calabro E et al. | 2012 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | cellular stress response (heat shock protein expression, cell viability and apoptosis) | 1,760 MHz | 0.086 W/kg | continuous for 2 h and 4 h | mobile phone, GSM, mobile communications |
Cao H et al. | 2015 | animal, rat/Sprague-Dawley, whole body | circadian concentration of melatonin, superoxide dismutase and glutathione peroxidase in blood | 1.8 GHz | 0.05653 W/kg | continuous for 2 h/day for 32 days | mobile phone, mobile communications |
Meena R et al. | 2014 | animal, rat/Wistar, whole body | oxidative stress and damage in the testes | 2.45 GHz | 0.14 W/kg | continuous for 2 h/day for 45 days | mobile communications, microwaves, 2.45 GHz, co-exposure |