Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1713 studies in total
  1. 748 studies
  2. 570 studies
  3. 513 studies
  4. 225 studies
  5. 205 studies
  6. 118 studies

DNA, proteins, and oxidative stress

570 studies in total
  1. 312 studies
  2. 199 studies
  3. 122 studies
  4. 42 studies
Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Luukkonen J et al. 2010 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) DNA damage, reactive oxygen species production 872 MHz 5 W/kg continuous for 1 h for the ROS production experiment; continuous for 3 hr for the comet assay experiment mobile phone, GSM, mobile communications, RF field, CW continuous wave, PW pulsed wave
Hook GJ et al. 2004 intact cell/cell culture, Molt-4 T (lymphoblastoid cells) DNA damage/DNA single-strand breaks, apoptosis 813.56 MHz 2.4 mW/kg–3.2 W/kg continuous for 2, 3 or 21 h iDEN, CDMA, FDMA, TDMA, mobile communications
Khalil AM et al. 2011 animal, mouse/BALB/c, whole body DNA damage/oxidative stress (levels of 8-hydroxy-2-deoxyguanosine in serum, brain and spleen) 900 MHz 1 W/kg 30 min/day for 30 days digital mobile phone, GSM, mobile communications, RF field
Khalil AM et al. 2012 animal, rat/Sprague-Dawley, whole body DNA damage/oxidative stress (urinary level of 8-hydroxy-2-deoxyguanosine) 1,800 MHz - continuous for 2 h mobile phone, GSM, mobile communications
McNamee JP et al. 2002 intact cell/cell culture DNA damage; formation of miconuclei 1.9 GHz 0.1–10 W/kg continuous for 2 h GSM, PCS, mobile communications, microwaves
Belyaev I et al. 2010 intact cell/cell culture, mesenchymal stem cells and primary cultures of human fibroblasts (VH-10) DNA double-strand breaks and double-strand break repair (53BP1 foci formation) 905 MHz 37–39 mW/kg continuous for 1 h, 2 h or 3 h mobile phone, GSM, UMTS, mobile communications
Cam ST et al. 2012 intact cell/cell culture, human, partial body: right ear DNA single-strand breaks 900 MHz 0.974 W/kg continuous for 15 min or 30 min digital mobile phone, GSM, mobile communications
Diem E et al. 2005 intact cell/cell culture, GFSH-R17 (transformed rat granulosa cells) and human diploid fibroblasts DNA single-strand breaks and double-strand breaks 1,800 MHz 1.2–2 W/kg continuous for 4, 16 and 24 h GSM, mobile communications
Belyaev IY et al. 2006 animal, rat/Fischer 344, whole body DNA strand breaks, changes in chromatin conformation, gene expression 915 MHz 0.4 mW/g continuous for 2 h GSM, mobile communications, microwaves
Hekmat A et al. 2013 DNA/RNA DNA structure 940 MHz 40 mW/kg continuous for 45 minutes mobile phone, mobile communications, RF field