The effects of exposure of honeybees to a 50 Hz electric field on the antioxidative and proteolytic system should be investigated.
One-day-old honeybee workers were divided into the following groups: exposure to an electric field of 1) 5.0 kV/m for 1 hour, 2) 5.0 kV/m for 3 hours, 3) 5.0 kV/m for 6 hours, 4) 11.5 kV/m for 1 hour, 5) 11.5 kV/m for 3 hours, 6) 11.5 kV/m for 6 hours, 7) 23.0 kV/m for 1 hour, 8) 23.0 kV/m for 3 hours, 9) 23.0 kV/m for 6 hours, 10) 34.5 kV/m for 1 hour, 11) 34.5 kV/m for 3 hours and 12) 34.5 kV/m for 6 hours. For each exposure duration (1 hour, 3 hours, 6 hours), a separate control group was used. Each group consisted of 10 cages with 100 bees, respectively.
Exposure | Parameters |
---|---|
Exposure 1:
50 Hz
Exposure duration:
1 hour
|
|
Exposure 2:
50 Hz
Exposure duration:
3 hours
|
|
Exposure 3:
50 Hz
Exposure duration:
6 hours
|
|
Exposure 4:
50 Hz
Exposure duration:
1 hour
|
|
Exposure 5:
50 Hz
Exposure duration:
3 hours
|
|
Exposure 6:
50 Hz
Exposure duration:
6 hours
|
|
Exposure 7:
50 Hz
Exposure duration:
1 hour
|
|
Exposure 8:
50 Hz
Exposure duration:
3 hours
|
|
Exposure 9:
50 Hz
Exposure duration:
6 hours
|
|
Exposure 10:
50 Hz
Exposure duration:
1 hour
|
|
Exposure 11:
50 Hz
Exposure duration:
3 hours
|
|
Exposure 12:
50 Hz
Exposure duration:
6 hours
|
|
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 1 hour |
Exposure source |
|
---|---|
Chamber | wooden cages (20 × 15 × 7 cm) |
Setup | a homogeneous (± 5%) electric field was generated by a plate capacitor with a distance of 20 cm between two electrodes constructed as a squared cage made out of wire mesh (dimension 100 cm × 100 cm) with a 10 mm× 10 mm grid diameter |
Additional info | the control groups were exposed to an electric field of < 2.00 kV/m |
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 3 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 6 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 1 hour |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 11.5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 3 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 11.5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 6 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 11.5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 1 hour |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 23 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 3 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 23 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 6 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 23 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 1 hour |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 34.5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 3 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 34.5 kV/m | - | measured | - | - |
Frequency | 50 Hz |
---|---|
Type | |
Exposure duration | 6 hours |
Exposure source |
|
---|
Measurand | Value | Type | Method | Mass | Remarks |
---|---|---|---|---|---|
electric field strength | 34.5 kV/m | - | measured | - | - |
All exposure groups showed a significant increase compared to the respective control groups in one or more enzyme activities of the antioxidant and proteolytic systems.
The authors conclude that exposure to a 50 Hz electric field might affect the antioxidative and proteolytic system of honeybees.