Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Zhong C et al. | 2012 | intact cell/cell culture, mesenchymal bone marrow stem cells of mice (rat?, remark EMF-Portal: contradictory information) | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Chen G et al. | 2012 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/S288C | GSM, mobile communications, RF, PW pulsed wave, magnetic field, low frequency, 50/60 Hz | 0.4 mT |
Huwiler SG et al. | 2012 | bacterium, <i>Escherichia coli</i>/K12 MG1655 | magnetic field, 50/60 Hz, power transmission line | 1 mT |
Fedrowitz M et al. | 2012 | animal, rat/Fischer 344 and Lewis, whole body | magnetic field, low frequency, 50/60 Hz | 100 µT |
Patruno A et al. | 2012 | intact cell/cell culture, THP-1 cells (human monocytic leukemia cell line) | magnetic field, low frequency, 50/60 Hz, co-exposure | 1 mT |
Bouwens M et al. | 2012 | intact cell/cell culture, Detroit 562 cells (human pharyngeal cells), THP-1 cells (human monocytic leukemia cell line) and human monocytes | magnetic field, low frequency, 50/60 Hz | 5 µT |
Shin EJ et al. | 2011 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz, co-exposure | 0.3–2.4 mT |
Sulpizio M et al. | 2011 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz | 1 mT |
Zhou J et al. | 2011 | intact cell/cell culture, osteoblasts | magnetic field, low frequency, 50/60 Hz | 0.9–4.8 mT |
Gomez-Ochoa I et al. | 2011 | intact cell/cell culture, mononuclear cells (from human peripheral blood) | magnetic field, signals/pulses, 50/60 Hz, electrotherapy | 2.25 mT |
Heredia-Rojas JA et al. | 2010 | intact cell/cell culture, INER-37 (human non-small-cell lung cancer cell line) and RMA E7 cells (E7-transfected mouse RMA lymphoma cells), transfected with the plasmid pEMF (electromagnetic field plasmid containing hsp70 promotor and the luciferase gene as reporter gene) | magnetic field, 50/60 Hz | 8–80 µT |
Reyes-Guerrero G et al. | 2010 | animal, rat/Wistar, whole body | magnetic field, low frequency, 50/60 Hz | 1 mT |
Patruno A et al. | 2010 | intact cell/cell culture, HaCaT cells (human keratinocytes) | magnetic field, low frequency, 50/60 Hz, electrotherapy | 1 mT |
Girgert R et al. | 2009 | intact cell/cell culture, MCF-7 (breast cancer cell line, p40 and p181 clone) | magnetic field, low frequency, 50/60 Hz | 1.2 µT |
Wang X et al. | 2008 | bacterium, <i>Magnetospirillum magneticum</i>/AMB-1 | magnetic field, geomagnetic field, 50/60 Hz | 0–1 mT |
Masiuk M et al. | 2008 | intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells), K-562 (chronic myelogenous leukemia) | magnetic field, 50/60 Hz | 10–20 mT |
Falone S et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 0.1 mT |
Benfante R et al. | 2008 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, signals/pulses, 50/60 Hz, power transmission line | 1–2 mT |
Delle Monache S et al. | 2008 | intact cell/cell culture, human vein endothelial cells (HUVEC) | magnetic field, low frequency, 50/60 Hz | 1 mT |
Vianale G et al. | 2008 | intact cell/cell culture, HaCaT cells (human keratinocytes) | magnetic field, 50/60 Hz | 1 mT |
Schmidt-Rohlfing B et al. | 2008 | intact cell/cell culture, chondrocytes (from human articular cartilage of osteoarthritic knee joints) | magnetic field, low frequency, signals/pulses, 50/60 Hz, electrotherapy | 2 mT |
Girgert R et al. | 2008 | intact cell/cell culture, MCF-7 (breast cancer cell line, p40 and p181 clone) | magnetic field, low frequency, 50/60 Hz | 1.2 µT |
Kanitz MH et al. | 2007 | intact cell/cell culture, SF767 (human glioma cell line) | magnetic field, 50/60 Hz, electrotherapy, therapeutic/medical device | 1.2 µT |
Henderson B et al. | 2006 | intact cell/cell culture, human umbilical venous endothelial cells | magnetic field, 50/60 Hz | 10–700 µT |
Lupke M et al. | 2006 | intact cell/cell culture, human umbilical cord blood-derived monocytes | magnetic field, 50/60 Hz | 1 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.