Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Ozlem-Caliskan S et al. | 2016 | - | magnetic field, 50/60 Hz, signals/pulses | - |
Isaković J et al. | 2024 | intact cell/cell culture, neural stem cells derived from B6 albino mouse embryos | magnetic field, 50/60 Hz, signals/pulses | - |
Moraveji M et al. | 2021 | intact cell/cell culture, rat adipose-derived mesenchymal stem cells | magnetic field, 50/60 Hz, signals/pulses, also other exposures without EMF, co-exposure | - |
Dehghani-Soltani S et al. | 2021 | intact cell/cell culture, A172 (human glioblastoma cells) and T98 cell line | magnetic field, 50/60 Hz, signals/pulses, co-exposure, also other exposures without EMF | 7 mT |
Wang X et al. | 2008 | bacterium, <i>Magnetospirillum magneticum</i>/AMB-1 | magnetic field, geomagnetic field, 50/60 Hz | 0–1 mT |
Lagroye I et al. | 1998 | intact cell/cell culture, primary (RTE cells) and spontaneously immortalized (RTSV cell line) and immortalized gamma radiation-treated (TCIV cell line) rat tracheal epithelial cells | magnetic field, geomagnetic field, 50/60 Hz, co-exposure, also other exposures without EMF | 55–104 µT |
Volpe P et al. | 2005 | intact cell/cell culture, FL cells (Friend erythroleukemia cells) | magnetic field, geomagnetic field, 50/60 Hz, shielding/field deprivation | 0.0025 nT–70 µT |
Goodman R et al. | 1992 | intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells) | magnetic field, low frequency, 50/60 Hz | 0.57–570 µT |
Luceri C et al. | 2005 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>/strain DBY747) | magnetic field, low frequency, 50/60 Hz | 0.1–100 µT |
Girgert R et al. | 2008 | intact cell/cell culture, MCF-7 (breast cancer cell line, p40 and p181 clone) | magnetic field, low frequency, 50/60 Hz | 1.2 µT |
Delle Monache S et al. | 2008 | intact cell/cell culture, human vein endothelial cells (HUVEC) | magnetic field, low frequency, 50/60 Hz | 1 mT |
Girgert R et al. | 2009 | intact cell/cell culture, MCF-7 (breast cancer cell line, p40 and p181 clone) | magnetic field, low frequency, 50/60 Hz | 1.2 µT |
Reyes-Guerrero G et al. | 2010 | animal, rat/Wistar, whole body | magnetic field, low frequency, 50/60 Hz | 1 mT |
Zhou J et al. | 2011 | intact cell/cell culture, osteoblasts | magnetic field, low frequency, 50/60 Hz | 0.9–4.8 mT |
Bouwens M et al. | 2012 | intact cell/cell culture, Detroit 562 cells (human pharyngeal cells), THP-1 cells (human monocytic leukemia cell line) and human monocytes | magnetic field, low frequency, 50/60 Hz | 5 µT |
Fedrowitz M et al. | 2012 | animal, rat/Fischer 344 and Lewis, whole body | magnetic field, low frequency, 50/60 Hz | 100 µT |
Zhong C et al. | 2012 | intact cell/cell culture, mesenchymal bone marrow stem cells of mice (rat?, remark EMF-Portal: contradictory information) | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Savage Jr RE et al. | 2005 | intact cell/cell culture, SF767 (human glioma cell line) | magnetic field, low frequency, 50/60 Hz | 1.2 µT |
Delle Monache S et al. | 2013 | intact cell/cell culture, human umbilical vein endothelial cells (HUVEC) and mouse pancreatic endothelial cell line (MS-1) | magnetic field, low frequency, 50/60 Hz | 1–2 mT |
Aikins AR et al. | 2017 | - | magnetic field, low frequency, 50/60 Hz | - |
Mansoury F et al. | 2021 | intact cell/cell culture | magnetic field, low frequency, 50/60 Hz | 0.25–2 mT |
Ozturk H et al. | 2022 | animal, rat/Sprague Dawley | magnetic field, low frequency, 50/60 Hz | - |
Kwiatkowski P et al. | 2022 | bacterium, <i>Staphylococcus aureus</i> FRI913 | magnetic field, low frequency, 50/60 Hz | - |
Tekutskaya E et al. | 2023 | DNA/RNA | magnetic field, low frequency, 50/60 Hz | - |
Ebrahimi M et al. | 2019 | mouse/BALB/c | magnetic field, low frequency, 50/60 Hz | - |
Nakasono S et al. | 2000 | bacterium, <i>Escherichia coli</i>/K12 | magnetic field, low frequency, 50/60 Hz, co-exposure | 7.8–14 mT |
Grassi C et al. | 2004 | intact cell/cell culture, human neuroblastoma cell line (IMR 32) and rat pituitary (GH3) cell line | magnetic field, low frequency, 50/60 Hz, co-exposure | 200–500 µT |
Patruno A et al. | 2012 | intact cell/cell culture, THP-1 cells (human monocytic leukemia cell line) | magnetic field, low frequency, 50/60 Hz, co-exposure | 1 mT |
Patruno A et al. | 2010 | intact cell/cell culture, HaCaT cells (human keratinocytes) | magnetic field, low frequency, 50/60 Hz, electrotherapy | 1 mT |
Baek S et al. | 2014 | intact cell/cell culture, mouse fibroblasts, transfected with lentivirus with OKSM gene constructs from HEK293 cells | magnetic field, low frequency, 50/60 Hz, shielding/field deprivation | 1 mT |
Goodman R et al. | 1991 | intact cell/cell culture, isolated organ, salivary gland, HL-60 (human acute myeloid leukaemia) cell line and partially dissected salivary glands from fruit flies (<i>Drosophila</i>) and fungus gnats (<i>Sciara</i>) | magnetic field, low frequency, signals/pulses, 50/60 Hz | 0.57 µT–19 mT |
Goodman R et al. | 1989 | intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells) | magnetic field, low frequency, signals/pulses, 50/60 Hz | 0.38–3.5 mT |
Kim YM et al. | 2016 | intact cell/cell culture, B16F10 (murine melanoma cells) | magnetic field, low frequency, signals/pulses, 50/60 Hz | - |
Cadossi R | 1990 | intact cell/cell culture, human peripheral blood lymphocytes (from normal donors, donors with chronic lymphocytic leukemia, and elderly donors), animal, C3H mice, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz, co-exposure | - |
Schmidt-Rohlfing B et al. | 2008 | intact cell/cell culture, chondrocytes (from human articular cartilage of osteoarthritic knee joints) | magnetic field, low frequency, signals/pulses, 50/60 Hz, electrotherapy | 2 mT |
Battini R et al. | 1991 | animal, rat/Wistar albino, whole body | magnetic field, signals/pulses, 50/60 Hz | 8 mT |
Tunik S et al. | 2013 | animal, rat/Wistar albino, whole body | magnetic field, signals/pulses, 50/60 Hz | 1.5 mT |
Urnukhsaikhan E et al. | 2016 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs) | magnetic field, signals/pulses, 50/60 Hz | 10 mT |
Jiang Y et al. | 2016 | animal, rat/Sprague Dawley | magnetic field, signals/pulses, 50/60 Hz | 4 mT |
Ardeshirylajimi A et al. | 2015 | intact cell/cell culture, human induced pluripotent stem cells | magnetic field, signals/pulses, 50/60 Hz | 1.5 mT |
Xie YF et al. | 2016 | intact cell/cell culture, rat calvarial osteoblasts | magnetic field, signals/pulses, 50/60 Hz | 0.6 mT |
Urnukhsaikhan E et al. | 2017 | animal, mouse/C57B6, whole body | magnetic field, signals/pulses, 50/60 Hz | 10 mT |
Keyan Z et al. | 2023 | animal, rat/Sprague-Dawley | magnetic field, signals/pulses, 50/60 Hz | - |
Li Y et al. | 2014 | intact cell/cell culture, dorsal root ganglion neurons (rat/Sprague-Dawley) | magnetic field, signals/pulses, 50/60 Hz, co-exposure | 0.1–100 mT |
Moraveji M et al. | 2016 | intact cell/cell culture, human dermal papilla mesenchymal cells | magnetic field, signals/pulses, 50/60 Hz, co-exposure | 1 mT |
Gomez-Ochoa I et al. | 2011 | intact cell/cell culture, mononuclear cells (from human peripheral blood) | magnetic field, signals/pulses, 50/60 Hz, electrotherapy | 2.25 mT |
Benfante R et al. | 2008 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, signals/pulses, 50/60 Hz, power transmission line | 1–2 mT |
Goodman R et al. | 1988 | isolated organ, salivary glands from <i>Sciara coprophila</i> (Insecta, Diptera) | magnetic field, signals/pulses, 50/60 Hz, therapeutic/medical device | 0.38–3.5 mT |
Caliogna L et al. | 2022 | intact cell/cell culture, human adipose-derived mesenchymal stem cells and primary human osteoblasts | magnetic field, signals/pulses, 50/60 Hz, therapeutic/medical device | - |
Lim HM et al. | 2021 | intact cell/cell culture, human dental pulp stem cells | magnetic field, signals/pulses, low frequency, 50/60 Hz | 10 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.