Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Dominici L et al. | 2011 | human, whole body | magnetic field, 50/60 Hz, high volt./current device/welder, occupational | 0.03–345.06 µT |
Giorgi G et al. | 2011 | bacterium, <i>E. coli</i>/Lac Z- (contains a plasmid with Tn10 derivative element expressing beta-galactosidase after transposition)); SURE (donor; carries plasmid F+ and transposon Tn5; kanamycin/chloramphenicol-resistent) & DK1 (recipient; streptomycin-resistent) | magnetic field, low frequency, signals/pulses, 50/60 Hz | 1 mT |
Sarimov R et al. | 2011 | intact cell/cell culture, human lymphocytes | magnetic field, static magnetic field, 50/60 Hz, DC | 20–43 µT |
Verschaeve L et al. | 2011 | bacterium, <i>Salmonella typhimurium</i>/TA-104-recN2-4 (with luciferase gene and recN promoter: produces light when DNA is damaged) & TA104-pr1 (with lux gene under a constitutive promoter: light production not influenced by genotoxic compounds (internal control)) | magnetic field, low frequency, 50/60 Hz, co-exposure | 100–500 µT |
Luukkonen J et al. | 2011 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, low frequency, 50/60 Hz, co-exposure | 100 µT |
Gadhia P et al. | 2010 | human, whole body | magnetic field, 50/60 Hz, occupational, co-exposure | - |
Ruiz-Gomez MJ et al. | 2010 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/WS8105-1C (genotype <i>MATalpha, ade2, arg4-17, trp1-289, ura3-52</i>: a marker which stains the colonies red) | magnetic field, static magnetic field, 50/60 Hz, DC | 0.35–2.45 mT |
Kim J et al. | 2010 | intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line) and IMR90 (human lung fibroblasts) | magnetic field, 50/60 Hz | 3–6 mT |
Mariucci G et al. | 2010 | animal, mouse/CD-1, whole body | magnetic field, 50/60 Hz | 1 mT |
Ruiz-Gomez MJ et al. | 2010 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/wild type (WS8105-1C) and <i>rad52 hdf1</i> mutants (<i>rad52</i>, <i>hdf1</i>, <i>rad52 hdf1</i>; radiation sensitive 52, high affinity DNA binding factor 1) | magnetic field, 50/60 Hz | 2.45 mT |
Okudan N et al. | 2010 | animal, mouse/Swiss albino, whole body | magnetic field, low frequency, 50/60 Hz | 5 µT |
Focke F et al. | 2010 | intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line), MRC-5 (human primary fetal lung fibroblasts), and human primary fibroblasts | low frequency, 50/60 Hz, power transmission line, magnetic field | 1 mT |
Celikler S et al. | 2009 | human, whole body | electric field, magnetic field, 50/60 Hz, power transmission line, electrical substation, occupational | 0.25–17 A/m |
Burdak-Rothkamm S et al. | 2009 | intact cell/cell culture, human fibroblasts | magnetic field, 50/60 Hz | 50–1,000 µT |
Albert GC et al. | 2009 | human, whole body | magnetic field, 50/60 Hz | 200 µT |
Yokus B et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100–500 µT |
Cellini L et al. | 2008 | bacterium, <i>Escherichia coli</i>/ATCC 700926 | magnetic field, low frequency, 50/60 Hz | 0.1–1 mT |
Koyama S et al. | 2008 | intact cell/cell culture, A172 (human glioblastoma cells) | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Cho YH et al. | 2007 | intact cell/cell culture, CCD-986sk (human fibroblasts) | magnetic field, low frequency, 50/60 Hz, co-exposure | 0.8 mT |
Erdal N et al. | 2007 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 1 mT |
Wahab MA et al. | 2007 | intact cell/cell culture | magnetic field, 50/60 Hz | 1 µT–1 mT |
Mairs RJ et al. | 2007 | intact cell/cell culture, UVW (human glioma cell line) | magnetic field, 50/60 Hz | 1 mT |
Hone P et al. | 2006 | intact cell/cell culture | magnetic field, 50/60 Hz, co-exposure | 0.23–0.7 mT |
Frahm J et al. | 2006 | intact cell/cell culture, macrophages (mouse) | magnetic field, 50/60 Hz | 0.05–1 mT |
Udroiu I et al. | 2006 | animal, mouse/CD-1 Swiss, whole body | magnetic field, low frequency, 50/60 Hz | 650 µT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.