Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2073 studies in total
  1. 775 studies
  2. 644 studies
  3. 523 studies
  4. 418 studies
  5. 333 studies
  6. 211 studies

Cells

523 studies in total
  1. 258 studies
  2. 128 studies
  3. 102 studies
  4. 90 studies
  5. 88 studies
  6. 69 studies
  7. 7 studies
Authors Year Exposed system Parameters Magnetic flux density/field strength
Colciago A et al. 2024 intact cell/cell culture, Schwann cells (from sciatic nerves of neonatal rats) magnetic field, 50/60 Hz -
Nieminen V et al. 2024 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF -
Sendera A et al. 2024 intact cell/cell culture, human adipose-derived mesenchymal stem cells magnetic field, 50/60 Hz, low frequency -
Ramazi S et al. 2023 intact cell/cell culture, MCF-7 (human breast cancer cell line) and HFF cells (human foreskin fibroblast cells) magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure -
Alipour M et al. 2022 intact cell/cell culture, rat bone marrow-derived mesenchymal cells (BMSCs) static magnetic field, magnetic field, 50/60 Hz, co-exposure -
Cios A et al. 2021 intact cell/cell culture, HEK293 (kidney cells), 786-O, 769-P, and Caki1 (clear cell renal carcinoma cell lines) magnetic field, 50/60 Hz 4.5 mT
Xu A et al. 2020 - magnetic field, 50/60 Hz, low frequency -
Yadamani S et al. 2020 - magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure -
Wang Y et al. 2019 intact cell/cell culture, human ventricular cardiomyocytes cell line (AC16), animal, rat/Sprague Dawley, whole body 50/60 Hz, magnetic field 100 µT
Salinas-Asensio MM et al. 2019 - magnetic field, 50/60 Hz, low frequency, signals/pulses, co-exposure, therapeutic/medical device -
Gaafar RM et al. 2018 plant, broad Bean (<i>Vicia faba</i>) 50/60 Hz, power transmission line, magnetic field, electric field 720–4,051 µT
Sun C et al. 2018 intact cell/cell culture, mouse embryonic fibroblasts (wild type and <i>Atm</i>-deficient) 50/60 Hz, magnetic field 2 mT
Solek P et al. 2018 - 50/60 Hz, magnetic field -
Koziorowska A et al. 2017 intact cell/cell culture, pig anterior pituitary gland cells magnetic field, 50/60 Hz, low frequency 2–6 mT
Koziorowska A et al. 2017 intact cell/cell culture, human neonatal fibroblast BJ 50/60 Hz, magnetic field, low frequency, signals/pulses 2.5 mT
Su L et al. 2017 intact cell/cell culture, U251 and A127 (human glioblastoma cell lines), SH-SY5Y (human neuroblastoma cell line), rat astrocytes, rat microglia, primary cortical neurons (of rat) magnetic field, low frequency, 50/60 Hz 2 mT
Solek P et al. 2017 intact cell/cell culture, GC-1 cells (murine spermatogonia cell line); GC-2 cells (murine spermatocyte cell line) magnetic field, 50/60 Hz, signals/pulses 2.5–8 mT
Akbarnejad Z et al. 2017 intact cell/cell culture, U87 (human glioblastoma cell line) magnetic field, signals/pulses, 50/60 Hz 5–10 mT
Luukkonen J et al. 2017 intact cell/cell culture, human neuroblastoma cell line (SH-SY5Y) magnetic field, 50/60 Hz, co-exposure 100 µT
Martinez MA et al. 2016 intact cell/cell culture, NB69 cells (human neuroblastoma cells) magnetic field, 50/60 Hz, co-exposure 100 µT
Liu Y et al. 2016 intact cell/cell culture, GC-2 cells (murine spermatocyte-derived cell line) magnetic field, 50/60 Hz 1–3 mT
Jin H et al. 2015 intact cell/cell culture, L123 cells (human lung epithelial cells) magnetic field, 50/60 Hz, co-exposure 1–2 mT
An GZ et al. 2015 intact cell/cell culture, BALB/3T3 cells (embryonal mouse fibroblasts) magnetic field, 50/60 Hz 2.3 mT
Giorgi G et al. 2014 intact cell/cell culture, human neuroblastoma cell line (BE(2)C) magnetic field, 50/60 Hz, co-exposure 1 mT
Huang CY et al. 2014 intact cell/cell culture, human epidermal keratinocytes (derived from neonatal foreskin) and HaCaT cells (human keratinocytes) magnetic field, 50/60 Hz 1.5 mT