Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Maaroufi K et al. | 2014 | animal, rat/Long-Evans, whole body | level of dopamine and serotonin, oxidative stress in brain, spatial learning and memory | 900 MHz | 0.05–0.18 W/kg | 1 hour per day for 21 consecutive days | mobile phone, mobile communications, co-exposure |
Cao H et al. | 2015 | animal, rat/Sprague-Dawley, whole body | circadian concentration of melatonin, superoxide dismutase and glutathione peroxidase in blood | 1.8 GHz | 0.05653 W/kg | continuous for 2 h/day for 32 days | mobile phone, mobile communications |
Hirose H et al. | 2006 | intact cell/cell culture, A172 (human glioblastoma cells) and IMR90 fibroblasts (from fetal lungs) | apoptosis, cellular stress response | 2.1425 GHz | 80–800 mW/kg | continuous for 24 or 48 h | mobile phone base station, CDMA, mobile communications |
Hirose H et al. | 2007 | intact cell/cell culture, A172 (human glioblastoma cells) and IMR90 fibroblasts (from fetal lungs) | cellular stress response (Hsp27 (heat-shock protein 27) content and hsp27 phosphorylation) | 2.1425 GHz | 80–800 mW/kg | continuous for 2, 24, or 48 h for A172 cells | mobile phone base station, CDMA, mobile communications, microwaves |
Calabro E et al. | 2012 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | cellular stress response (heat shock protein expression, cell viability and apoptosis) | 1,760 MHz | 0.086 W/kg | continuous for 2 h and 4 h | mobile phone, GSM, mobile communications |
Sefidbakht Y et al. | 2014 | intact cell/cell culture, HEK 293T cells (human embryonic kidney cells) transfected with luciferase gene | luciferase enzyme activity and oxidative stress | 940 MHz | 0.09 W/kg | continuous for up to 90 minutes | mobile phone, mobile communications |
Sokolovic D et al. | 2008 | animal, rat/Wistar albino, whole body | oxidative stress in the brain | 900 MHz | 0.135 W/kg | repeated daily exposure, 4 h/day, for 20, 40, and 60 days | digital mobile phone, GSM, mobile communications, microwaves |
Meena R et al. | 2014 | animal, rat/Wistar, whole body | oxidative stress and damage in the testes | 2.45 GHz | 0.14 W/kg | continuous for 2 h/day for 45 days | mobile communications, microwaves, 2.45 GHz, co-exposure |
Kumari K et al. | 2012 | animal, rat/Wistar, whole body | effects on liver: oxidative stress and liver values | 900 MHz | 0.15 W/kg | continuous for 2 hours/day for 35 days | mobile phone, GSM, mobile communications, microwaves, 2.45 GHz |
Dasdag S et al. | 2009 | animal, rat/Wistar albino, partial body: head | apoptosis and oxidative stress in the brain | 900 MHz | 0.17–0.58 W/kg | continuous for 2 hr/day, 7 days/week for 10 months | mobile communications, mobile phone, GSM, microwaves |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.