Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Al-Damegh MA 2012 animal, rat/Wistar, whole body histopathological alterations in the testis, oxidative stress in blood and testis 900–1,900 MHz 0.9 W/kg continuous for 15, 30 or 60 min/day during 14 days digital mobile phone, GSM, mobile communications, co-exposure
Zmyslony M et al. 2004 intact cell/cell culture, rat lymphocytes intracellular concentration of reactive oxygen species 930 MHz 1.5 W/kg continuous for 5 or 15 min mobile communications, mobile phone, CW continuous wave
Maaroufi K et al. 2014 animal, rat/Long-Evans, whole body level of dopamine and serotonin, oxidative stress in brain, spatial learning and memory 900 MHz 0.05–0.18 W/kg 1 hour per day for 21 consecutive days mobile phone, mobile communications, co-exposure
Güler G et al. 2010 animal, rabbit/New Zealand White, whole body lipid peroxidation and DNA damage in the brain 1,800 MHz - continuous for 15 min/day on 7 days - from day 15 to day 22 of gestation mobile phone, GSM, mobile communications
Bodera P et al. 2015 animal, rat/Wistar, whole body lipid peroxidation in brain, blood, liver and kidney 1,800 MHz 0.024–0.028 W/kg continuous for 15 minutes/day for 5 days mobile phone base station, GSM, TDMA, mobile communications, co-exposure
Sefidbakht Y et al. 2014 intact cell/cell culture, HEK 293T cells (human embryonic kidney cells) transfected with luciferase gene luciferase enzyme activity and oxidative stress 940 MHz 0.09 W/kg continuous for up to 90 minutes mobile phone, mobile communications
Kerimoglu G et al. 2016 animal, rat/Sprague-Dawley, whole body morphology and oxidative stress in the heart 900 MHz 0.0093 W/kg 1 h/day between postnatal days 21 and 59 mobile phone, mobile communications
Finnie JW et al. 2006 animal, mouse/BALB/c, whole body neural stress of fetal brain 900 MHz 4 W/kg repeated daily exposure, 60 min/day from day 1 to day 19 of gestation digital mobile phone, GSM, mobile communications, microwaves
Xu S et al. 2010 intact cell/cell culture oxidative DNA damage 1,800 MHz 2 W/kg 5 min on - 10 min off - for 24 hr mobile phone, GSM, mobile communications, RF field, PW pulsed wave
Sahin D et al. 2016 animal, rat/Wistar albino, whole body oxidative DNA damage in the brain 2,100 MHz 0.4 W/kg 6 h/day on 5 consecutive days/week for 2 weeks mobile phone, UMTS, mobile communications