Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Yurekli AI et al. | 2006 | animal, rat/Wistar albino, whole body | oxidative stress | 945 MHz | 11.3 mW/kg | repeated daily exposure, 7 h/day, for 8 days | mobile phone base station, GSM, mobile communications |
Hässig M et al. | 2014 | animal, cow/Simmental and Brown Swiss, whole body | oxidative stress in the blood of cattle | 900 MHz | - | intermittent exposure for min. 6 h 36 min, max. 19 h and 16 h 43 min on average per day with a standard deviation of 3 h 03 min for 30 days | mobile phone base station, GSM, mobile communications, PW pulsed wave |
Jelodar G et al. | 2013 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the eye | 900 MHz | - | continuous for 4 h/day on 45 days | mobile phone base station, mobile communications |
Jelodar G et al. | 2013 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the testes | 900 MHz | - | continuous for 4 h/day for 45 days | mobile phone base station, mobile communications |
Marzook EM et al. | 2014 | animal, rat/albino | oxidative stress and other parameters in the blood | 900 MHz | - | continuous for 24 h/day for 8 weeks | mobile phone base station, mobile communications, co-exposure |
Akbari A et al. | 2014 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the rat brain | 900 MHz | - | continuous for 4 h/day for 45 days | mobile phone base station, mobile communications, co-exposure |
Hong MN et al. | 2012 | intact cell/cell culture, MCF10 A cells (human breast epithelial cells) | oxidative stress | 837 MHz | 2–4 W/kg | continuous for 2 h | mobile phone, CDMA, W-CDMA, mobile communications |
Lee JS et al. | 2016 | intact cell/cell culture, HT22 (mouse hippocampus neuronal cells) | cytotoxicity | 837–1,950 MHz | 2 W/kg | continuous for 2 hours | mobile phone, CDMA, W-CDMA, mobile communications, also other exposures without EMF, co-exposure |
Kang KA et al. | 2014 | intact cell/cell culture, NIH3T3 cells (mouse fibroblasts), U87 (human glioma cells), PC12 (rat pheochromocytoma cells), SH-SY5Y (human neuroblastoma cells) | cell viability, oxidative stress | 837–1,950 MHz | 2 W/kg | continuous for 2 hours | mobile phone, CDMA, W-CDMA, mobile communications, co-exposure |
Kesari KK et al. | 2011 | animal, rat/Wistar, whole body | oxidative stress and metabolism in the brain | 900 MHz | 0.9 W/kg | continuous for 2 h/day on 45 days | mobile phone, GSM, FDMA, TDMA, mobile communications, PW pulsed wave |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.