polycarbonate ventilated cages (45 cm x 20 cm x 35 cm, L x W x H) with room temperature of 22-25°C and relative humidity of 45-55%
Setup
exposure system consisted of an exposure device and a plastic rack, both made of acrylonitrile butadiene styrene plastic; the exposure device had five layers (200 cm x 100 cm x 200 cm, L x W x H) with a layer-to-layer distance of 35 cm; inside the exposure device, a plastic rack (140 cm x 70 cm x 200 cm, L x W x H) with four floors was placed; 24 plastic cages with 2-3 rats each were placed inside the system; bronze wires generated the uniform magnetic field; the wiring ratio of the five coils was 2:1:1:1:2 and the 3% uniformity area of each floor was 150 cm x 50 cm (L x W) and over the whole rack, uniformity was 5.2%; sound and temperature from the exposure system were close to those in the environment; exposure room was lacking other electric devices, e.g., computers and daylight lamps were kept far away from the system
Zhang Y et al.
(2020):
Examination of the Effect of a 50-Hz Electromagnetic Field at 500 μT on Parameters Related With the Cardiovascular System in Rats
Wang Y et al.
(2019):
Exposure to a 50 Hz magnetic field at 100 µT exerts no DNA damage in cardiomyocytes
Okano H et al.
(2017):
The physiological influence of alternating current electromagnetic field exposure on human subjects
Elmas O et al.
(2012):
Effects of short-term exposure to powerline-frequency electromagnetic field on the electrical activity of the heart
McNamee DA et al.
(2011):
The response of the human circulatory system to an acute 200-muT, 60-Hz magnetic field exposure
McNamee DA et al.
(2010):
The cardiovascular response to an acute 1800-microT, 60-Hz magnetic field exposure in humans
McNamee DA et al.
(2009):
A literature review: the cardiovascular effects of exposure to extremely low frequency electromagnetic fields
George I et al.
(2008):
Myocardial function improved by electromagnetic field induction of stress protein hsp70
Ghione S et al.
(2005):
Effects of 50 Hz electromagnetic fields on electroencephalographic alpha activity, dental pain threshold and cardiovascular parameters in humans
Jeong JH et al.
(2005):
Influence of exposure to electromagnetic field on the cardiovascular system
Ali FM et al.
(2003):
Effect of 50 Hz, 0.2 mT magnetic fields on RBC properties and heart functions of albino rats
Kurokawa Y et al.
(2003):
Can extremely low frequency alternating magnetic fields modulate heart rate or its variability in humans?
Sastre A et al.
(1998):
Nocturnal exposure to intermittent 60 Hz magnetic fields alters human cardiac rhythm
Willis RJ et al.
(1984):
Potential hazards of NMR imaging. No evidence of the possible effects of static and changing magnetic fields on cardiac function of the rat and guinea pig
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.