Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Zhong C et al. | 2012 | intact cell/cell culture, mesenchymal bone marrow stem cells of mice (rat?, remark EMF-Portal: contradictory information) | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Martinez MA et al. | 2012 | intact cell/cell culture, NB69 cells (human neuroblastoma cells) | magnetic field, low frequency, 50/60 Hz | 100 µT |
Zhang M et al. | 2013 | intact cell/cell culture, human epidermal stem cells | magnetic field, low frequency, 50/60 Hz | 5 mT |
Rageh MM et al. | 2012 | animal, rat/Wistar, whole body | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Delle Monache S et al. | 2013 | intact cell/cell culture, human umbilical vein endothelial cells (HUVEC) and mouse pancreatic endothelial cell line (MS-1) | magnetic field, low frequency, 50/60 Hz | 1–2 mT |
Bayir E et al. | 2015 | intact cell/cell culture, bacterium, <i>Staphylococcus aureus</i> and <i>Escherichia coli</i> O157:H7 | magnetic field, low frequency, 50/60 Hz | 2–4 mT |
Fijalkowski K et al. | 2015 | bacterium, <i>Staphylococcus aureus, Escherichia coli, Acinetobacter baumannii, Pseudomonas aeruginosa, Serratia marcescens, Streptococcus mutans, Cronobacter sakazaki, Klebsiella oxytoca, Staphylococcus xylosus</i> | magnetic field, low frequency, 50/60 Hz | 25–34 mT |
Tirono M | 2022 | intact cell/cell culture, <i>Lactobacillus acidophilus</i> | magnetic field, low frequency, 50/60 Hz | - |
Costantini E et al. | 2022 | - | magnetic field, low frequency, 50/60 Hz | - |
Ross SM | 1990 | intact cell/cell culture, rabbit-ligament fibroblast (RLF) cell line | magnetic field, low frequency, 50/60 Hz, DC, static magnetic field | 42–261 µT |
Woroszyło M et al. | 2021 | bacterium, <i>Staphylococcus aureus</i> | magnetic field, low frequency, 50/60 Hz, also other exposures without EMF, co-exposure | 8.1–8.5 mT |
Katsir G et al. | 1998 | intact cell/cell culture, primary chick embryo fibroblasts | magnetic field, low frequency, 50/60 Hz, co-exposure | 0.06–0.7 mT |
Grassi C et al. | 2004 | intact cell/cell culture, human neuroblastoma cell line (IMR 32) and rat pituitary (GH3) cell line | magnetic field, low frequency, 50/60 Hz, co-exposure | 200–500 µT |
Marcantonio P et al. | 2010 | intact cell/cell culture, BE(2)C cells (human neuroblastoma cells) | magnetic field, low frequency, 50/60 Hz, co-exposure | 1 mT |
Lee HJ et al. | 2012 | intact cell/cell culture, NIH3T3 cells (mouse fibroblasts), normal and transfected with a c-Myc-containing vector or with an empty vetor | magnetic field, low frequency, 50/60 Hz, co-exposure | 0.01–1 mT |
Trillo MA et al. | 2012 | intact cell/cell culture, Hep G2 cells (hepatic transformed cell line) and NB69 cells (neuroblastoma cells) | magnetic field, low frequency, 50/60 Hz, co-exposure | 100 µT |
Trillo MA et al. | 2013 | intact cell/cell culture, NB69 cells (neuroblastoma cells) | magnetic field, low frequency, 50/60 Hz, co-exposure | 10–100 µT |
Patruno A et al. | 2010 | intact cell/cell culture, HaCaT cells (human keratinocytes) | magnetic field, low frequency, 50/60 Hz, electrotherapy | 1 mT |
Shoorche AB et al. | 2023 | intact cell/cell culture, MG-63 cells (human osteosarcoma cell line) | magnetic field, low frequency, 50/60 Hz, signals/pulses | - |
Cecconi S et al. | 2000 | intact cell/cell culture, ovarian follicles from mice (Swiss CD1) | magnetic field, low frequency, signals/pulses, 50/60 Hz | 1.5 mT |
Wu H et al. | 2005 | intact cell/cell culture, mouse mesenchymal stem cells | magnetic field, low frequency, signals/pulses, 50/60 Hz | 2 mT |
Safari M et al. | 2016 | - | magnetic field, low frequency, signals/pulses, 50/60 Hz | - |
Cadossi R | 1990 | intact cell/cell culture, human peripheral blood lymphocytes (from normal donors, donors with chronic lymphocytic leukemia, and elderly donors), animal, C3H mice, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz, co-exposure | - |
Chen Y et al. | 2019 | bacterium, <i>Escherichia coli</i> Stamm DH5 | magnetic field, low frequency, static magnetic field, intermediate frequency, 50/60 Hz, DC | - |
Khalil AM et al. | 1991 | intact cell/cell culture, human peripheral blood | magnetic field, signals/pulses, 50/60 Hz | 1.05 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.