Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Electric field strength |
---|---|---|---|---|
Kanemaki M et al. | 2024 | - | electric field, low frequency, static electric field, 50/60 Hz | - |
Şenol N et al. | 2023 | animal, rat/ Wistar albino | 50/60 Hz, electric field, co-exposure, also other exposures without EMF | - |
Harakawa S et al. | 2022 | animal, mouse/BALB/c | electric field, 50/60 Hz | - |
Kanemaki M et al. | 2022 | blood samples | electric field, static electric field, low frequency, 50/60 Hz | - |
Tony SK et al. | 2022 | animal, rat/Sprague Dawley albino, whole body | 50/60 Hz, electric field, low frequency, also other exposures without EMF, co-exposure | 5.4 kV/m |
Khalil AM | 2021 | animal, mouse/albino | 50/60 Hz, magnetic field, electric field | 4 kV/m |
Bagheri Hosseinabadi M et al. | 2021 | human, whole body | magnetic field, 50/60 Hz, electric field, low frequency, occupational | 14.87–25.18 V/m |
Harakawa S et al. | 2020 | animal, mouse/BALB/c, whole body | electric field, 50/60 Hz | 10 kV/m |
Hosseinabadi MB et al. | 2020 | human | magnetic field, electric field, 50/60 Hz, low frequency, co-exposure | 4.89–44.82 V/m |
Harakawa S et al. | 2020 | animal, mouse/BALB/c, whole body | electric field, low frequency, 50/60 Hz | 10 kV/m |
Li K et al. | 2019 | - | electric field, 50/60 Hz, signals/pulses | - |
Di G et al. | 2018 | animal, mouse/ICR, whole body | electric field, static electric field, 50/60 Hz | 35 kV/m |
Hori T et al. | 2018 | animal, mouse/BALB/c, whole body | electric field, 50/60 Hz, co-exposure, shielding/field deprivation | 10 kV/m |
Xiao-Feng P et al. | 2017 | animal, rat/Wistar | 50/60 Hz, power transmission line, electric field, magnetic field | 4,000 V/m |
Hori T et al. | 2017 | animal, mouse/BALB/c, whole body | electric field, 50/60 Hz | 10 kV/m |
Harakawa S et al. | 2017 | animal, mouse/BALB/c, whole body | electric field, 50/60 Hz | 10 kV/m |
Tiwari R et al. | 2015 | human, whole body | electric field, magnetic field, low frequency, 50/60 Hz, electrical substation, occupational | - |
Calota V et al. | 2006 | serum samples | electric field, 50/60 Hz | 5–20 kV/cm |
Harakawa S et al. | 2005 | animal, rat/Sprague-Dawley, whole body | electric field, 50/60 Hz | 17,500 V/m |
Harakawa S et al. | 2004 | animal, rat/Wistar, whole body | electric field, 50/60 Hz, co-exposure | 17.5 kV/m |
Bonhomme-Faivre L et al. | 2003 | human, animal, mouse/Swiss, whole body | electric field, magnetic field, 50/60 Hz | 1 V/m–220 mV/cm |
Sobczak A et al. | 2002 | human, whole body | electric field, magnetic field, 50/60 Hz, occupational | 20 V/m |
Kula B et al. | 2002 | human, whole body | electric field, magnetic field, 50/60 Hz, occupational | 20 V/m |
Fernie KJ et al. | 2001 | animal, American kestrel (<i>Falco sparverius</i>), whole body | electric field, magnetic field, 50/60 Hz | 10 kV/m |
Kula B et al. | 1999 | human, whole body | electric field, magnetic field, 50/60 Hz, occupational | 20 V/m |
Burchard JF et al. | 1999 | animal, cow/Holstein, whole body | electric field, magnetic field, 50/60 Hz | 10 kV/m |
Zecca L et al. | 1998 | animal, rat/Sprague-Dawley, whole body | electric field, magnetic field, 50/60 Hz | 1–5 kV/m |
Johansson O et al. | 1994 | human | 50/60 Hz, PC/TV monitor, electric field, magnetic field, occupational | - |
Margonato V et al. | 1993 | animal, rat/Sprague-Dawley, whole body | electric field, 50/60 Hz | 25–100 kV/m |
Gamberale F et al. | 1989 | human, whole body | electric field, magnetic field, 50/60 Hz, power transmission line, occupational | 2.8 kV/m |
Wolpaw JR et al. | 1989 | animal, monkey/southern pig-tailed macaque (<i>Macaca nemestrina</i>), whole body | electric field, magnetic field, 50/60 Hz | 3–30 kV/m |
Seto YJ et al. | 1986 | animal, rat/Sprague-Dawley, whole body | electric field, 50/60 Hz | 80 kV/m |
Ragan HA et al. | 1983 | animal, rat/Sprague-Dawley, whole body | electric field, 50/60 Hz | 100 kV/m |
Marino AA et al. | 1980 | animal, mouse/HA/ICR, whole body | electric field, 50/60 Hz | 50 V/cm |
Fam WZ | 1980 | animal, mouse/ICR-SW, whole body | electric field, 50/60 Hz | 240 kV/m |
Marino AA et al. | 1976 | animal, rat/Sprague-Dawley, whole body | electric field, 50/60 Hz | 150 V/m |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.