Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1743 studies in total
  1. 770 studies
  2. 584 studies
  3. 519 studies
  4. 228 studies
  5. 208 studies
  6. 118 studies

Health

770 studies in total
  1. 157 studies
  2. 95 studies
  3. 86 studies
  4. 84 studies
  5. 80 studies
  6. 62 studies
  7. 59 studies
  8. 55 studies
  9. 54 studies
  10. 48 studies
  11. 34 studies
  12. 28 studies
  13. 26 studies
  14. 19 studies
  15. 16 studies
  16. 11 studies
  17. 9 studies
  18. 4 studies

Hypersensitivity/well-being/subjective complaints 54 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Koivisto M et al. 2001 human, partial body: head (left side) subjective symptoms or sensations 902 MHz - 1 session of 30 min or 2 sessions of 60 min each separated by 24 h digital mobile phone, GSM, mobile communications
Kaul G 2009 human, whole body, partial body: 30 cm from the head (in the case of GSM) field perception 50 Hz 0.75 µW/g 3 times 10 min mobile communications, digital mobile phone, GSM, magnetic field, 50/60 Hz
Verrender A et al. 2018 human, whole body symptoms and field perception 902–928 MHz - 30 min each exposure (6 x in double-blind study) GSM, UMTS, mobile communications, RF, W-LAN/WiFi
Augner C et al. 2012 human physiological measures (heart rate, heart rate variability, blood pressure), subjective symptoms (headache, nausea, fatigue, dizziness, skin irritation) 835–1,800 MHz - 5-180 min mobile phone, GSM, NMT, mobile communications
Nieto-Hernandez R et al. 2008 human perceived sensitivity; symptom severity; subjective belief about their symptoms - - 50 min ( 30 min without exposure - 50 min exposure or sham exposure - 30 min resting period without exposure) mobile phone, GSM, mobile communications
Mortazavi SM et al. 2011 human - - - continuous for 10 min digital mobile phone, GSM, mobile communications, microwaves
Wallace D et al. 2010 human, whole body electrosensitivity (well-being and different physiological responses) 420 MHz 271 µW/kg continuous for 15 min for the open provocation test, 2 times 5 min for the doble blind test mobile communications, TETRA/TETRAPOL, TDMA, RF
Sauter C et al. 2015 human, partial body: left side of the head working memory and attention, well-being 385 MHz 1.5–6 W/kg continuous for 2.5 hours TETRA/TETRAPOL, mobile communications
Zwamborn APM et al. 2003 human, whole body cognitive performance, well-being 945 MHz 0.000316 µW/kg–0.082 mW/kg continuous for 20 min mobile phone base station, GSM, UMTS, CDMA, TDMA, mobile communications
Hillert L et al. 2008 human, partial body: head (left side) electromagnetic field perception and symptoms (headache, vertigo, skin irritation and sensation of heat) 884 MHz 0.18–1.8 W/kg continuous for 3 h digital mobile phone, GSM, mobile communications