Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Aslan A et al. | 2017 | animal, rat/Sprague Dawley, whole body | cerebellar morphology | 900 MHz | 0.01 W/kg | 1 hour/day for 25 consecutive days | mobile communications, mobile phone |
Hussein S et al. | 2016 | animal, rat | changes and damage in the rat brain | 1,800 MHz | 0.6 W/kg | continuous for 120 min/day for three months | mobile phone, mobile communications |
Carballo-Quintas M et al. | 2011 | animal, rat/Sprague-Dawley, whole body | clinical signs of seizure or jerks; c-fos and GFAP expression in the brain | 900 MHz | 0.78–4.47 W/kg | continuous for 2 h | digital mobile phone, GSM, mobile communications, microwaves, PW pulsed wave, co-exposure |
Son Y et al. | 2015 | animal, mouse/C57BL/6, whole body | cognitive functions and hippocampal histology | 1,950 MHz | 5 W/kg | continuous for 2 hours/day for 60 days | mobile phone, W-CDMA, mobile communications |
Fritze K et al. | 1997 | animal, rat/Wistar, partial body: head | degenerative processes in the brain | 890–900 MHz | 0.17–17.5 W/kg | continuous for 4 h | GSM, mobile communications |
Umur AS et al. | 2013 | animal, chicken embryos/White Leghorn (eggs), whole body | development of the neural tube | - | 0.77 W/kg | standby mode for 30, 48 or 72 hours | mobile phone, mobile communications |
Ushiyama A et al. | 2007 | animal, rat/Sprague-Dawley | effects on blood-cerebrospinal fluid barrier permeability | 1.5 GHz | 0.5–10.4 W/kg | continuous for 30 min | PDC, TDMA, mobile communications |
Crouzier D et al. | 2007 | animal, rat/Sprague-Dawley, whole body | effects on cholinergic system | 1.8 GHz | 0.048–0.53 W/kg | continuous for 24 h | digital mobile phone, GSM, mobile communications, microwaves |
Inomata-Terada S et al. | 2007 | human, partial body: head (left side) | effects on motor cortex | 800 MHz | 0.054 W/kg | continuous for 30 min | digital mobile phone, TDMA, mobile communications, TMS (transcranial stimulation) |
Kim TH et al. | 2008 | animal, mouse/C57BL, partial body: head | effects on the brain (cell proliferation, cell death / apoptosis, distribution of neurons and glia cells) | 849 MHz | 1.55–7.8 W/kg | repeated daily exposure, 1 h/day, 5 days/week, for 6 or 12 months | digital mobile phone, PCS, CDMA, mobile communications |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.