Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Persson BR et al. | 1992 | animal, rat/Sprague-Dawley & Fischer 344, whole body | permeability of the blood-brain barrier | 915 MHz | - | continuous for 2 h | GSM, mobile communications, microwaves, magnetic field, static magnetic field |
Persson BRR et al. | 1997 | animal, rat/Fischer 344 | permeability of blood-brain barrier | 915 MHz | 8 mW/kg–8.3 W/kg | continuous for 2 min to 960 min | GSM, TDMA, mobile communications, microwaves |
Persson BRR et al. | 2005 | animal, rat/Fischer 344, whole body | - | 915 MHz | 0.2–200 mW/kg | not specified in the article | digital mobile phone, GSM, mobile communications, microwaves, CW continuous wave, PW pulsed wave |
Poulletier de Gannes F et al. | 2017 | animal, rat/Wistar-Han, partial body | - | 1,800–1,960 MHz | - | - | mobile phone, mobile communications, GSM, UMTS |
Salford LG et al. | 1993 | animal, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.33–3.3 W/kg | not specified | digital mobile phone, mobile communications, microwaves |
Salford LG et al. | 1994 | animal, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.016–5 W/kg | continuous for 2 h | GSM, mobile communications, microwaves |
Salford LG et al. | 2003 | animal, rat/Fischer 344, whole body | permeability of blood-brain-barrier | 915 MHz | 2–200 mW/kg | continuous for 2 hours | GSM, mobile communications, microwaves |
Schirmacher A et al. | 2000 | model of blood-brain barrier (consisting of astrocytes and capillary endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.8 GHz | 0.3–0.46 W/kg | continuous for 4 days | GSM, mobile communications |
Sirav B et al. | 2009 | animal, rat/Wistar albino, whole body | permeability of blood-brain barrier | 900 MHz | - | continuous for 20 min | mobile communications, mobile phone, RF, CW continuous wave |
Sirav B et al. | 2016 | animal, rat/Wistar albino, whole body | permeability of the blood brain barrier | 900 MHz | 0.02 W/kg | continuous for 20 minutes | mobile phone, GSM, mobile communications |