Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |
Perentos N et al. | 2007 | human, partial body: left hemisphere | EEG pattern | 900 MHz | 1.56 W/kg | intermittent, 3 x 15 min, see add. information | digital mobile phone, GSM, mobile communications |
Maby E et al. | 2004 | human, partial body: left or right ear | cerebral activity (auditory evoked potentials) | 900 MHz | 1.4 W/kg | - | GSM, mobile communications |
Vecchio F et al. | 2012 | human, partial body: left side of the head | cortical activity (EEG), visual reaction time task | 902.4 MHz | 0.5 W/kg | continuous for 45 min | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Vecchio F et al. | 2012 | human, partial body: left side of the head | cortical activity (EEG) | 902.4 MHz | 0.5 W/kg | continuous for 45 min | mobile phone, GSM, mobile communications |
Lustenberger C et al. | 2015 | human, partial body: left side of the head | sleep EEG | 900 MHz | 0.62–2.12 W/kg | continuous for 30 minutes (in each of 2 sessions) | mobile phone, mobile communications |
Kwon MS et al. | 2009 | human, partial body: left/right ear | mismatch negativity | 902 MHz | 0.82–1.21 W/kg | 1 h in 6 minute blocks | digital mobile phone, GSM, mobile communications |
Croft RJ et al. | 2010 | human, partial body: left/right hemisphere | resting EEG (alpha waves) | 894.6 MHz | 0.7–1.7 W/kg | continuous for 55 min | GSM, W-CDMA, mobile communications |
Leung S et al. | 2011 | human, partial body: left/right hemisphere | event-related potentials and performance during oddball paradigma and n-back task | 894.6 MHz | 0.7–1.7 W/kg | continuous for 55 min | GSM, W-CDMA, mobile communications |
Hladký A et al. | 1999 | human, partial body: right ear | EEG | 900 MHz | 0.1 W/kg | continuous for 5 or 6 min | GSM, TDMA, mobile communications |