Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Hou Q et al. | 2015 | intact cell/cell culture, NIH3T3 cells (mouse fibroblast cell line) | oxidative stress, DNA damage and apoptosis in mouse embryonic fibroblasts | 1,800 MHz | 2 W/kg | intermittent exposure (5 min on/10 min off) for 0.5, 1, 1.5, 2, 4, 6 or 8 hours | mobile phone, GSM, mobile communications |
Hässig M et al. | 2014 | animal, cow/Simmental and Brown Swiss, whole body | oxidative stress in the blood of cattle | 900 MHz | - | intermittent exposure for min. 6 h 36 min, max. 19 h and 16 h 43 min on average per day with a standard deviation of 3 h 03 min for 30 days | mobile phone base station, GSM, mobile communications, PW pulsed wave |
Narayanan SN et al. | 2014 | animal, rat/Wistar albino, whole body | oxidative stress in the brain | 890–915 MHz | 1.58 W/kg | intermittent for 1 h/day for 28 days | mobile phone, GSM, mobile communications |
Burlaka A et al. | 2013 | animal, Japanese quail, whole body: embryo <i>in ovo</i> | oxidative stress in quail embryos | 900 MHz | 3 µW/kg | intermittent for 158 h: 48 sec "on" (speech mode), 12 sec "off" | mobile phone, GSM, mobile communications, RF |
Liu K et al. | 2014 | intact cell/cell culture, GC-2 cells (murine spermatocyte-derived cell line) | - | 1,800 MHz | 1–4 W/kg | intermittent for 24 hours (5 min on and 10 min off) | mobile phone, GSM, mobile communications |
Balci M et al. | 2007 | animal, rat/Wistar albino, whole body | effects on oxidant/antioxidant balance in cornea and eye lens | 900 MHz | 1.2 W/kg | intermittent, 4 x 10 min/day, for 4 weeks | digital mobile phone, GSM, mobile communications |
Yao K et al. | 2008 | intact cell/cell culture, SRA01/04-hLEC (human eye lens epithelial cells) | DNA damage, intracellular reactive oxygen species formation | 30–90 Hz | 1–4 W/kg | intermittent, 5 min on/10 min off, for 2 h | digital mobile phone, GSM, mobile communications, microwaves |
Chauhan V et al. | 2006 | intact cell/cell culture, TK6 cells (lymphoblastoma cells) | cellular stress response | 1.9 GHz | 1–10 W/kg | intermittent, 5 min on/10 min off, for 6 h | digital mobile phone, mobile communications |
Özgüner F et al. | 2006 | animal, rat/Sprague-Dawley, whole body | oxidative stress-induced retinal impairment | 900 MHz | 0.016–4 W/kg | repeated daily exposure for 30 min/day for 60 days | GSM, mobile communications |
Ilhan A et al. | 2004 | animal, rat/Wistar, partial body: head | oxidative stress | 900 MHz | 0.25–2 W/kg | repeated daily exposure, 1 h/day for 7 days | analog mobile phone, GSM, mobile communications |