Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Zeni O et al. | 2005 | intact cell/cell culture, human peripheral blood leukocytes | occurence of DNA damages | 900 MHz | 0.3–1 W/kg | continuous for 2 h | GSM, mobile communications, microwaves |
Baohong W et al. | 2005 | intact cell/cell culture | DNA damage | 1.8 GHz | 3 W/kg | continuous for 2 h | GSM, mobile communications, microwaves |
Belyaev IY et al. | 2006 | animal, rat/Fischer 344, whole body | DNA strand breaks, changes in chromatin conformation, gene expression | 915 MHz | 0.4 mW/g | continuous for 2 h | GSM, mobile communications, microwaves |
Lixia S et al. | 2006 | intact cell/cell culture, SRA01/04-hLEC (human eye lens epithelial cells) | comet assay, stress response/gene expression, cell proliferation | 1.8 GHz | 1–3 W/kg | continuous for 2 h | digital mobile phone, GSM, TDMA, mobile communications |
Perrin A et al. | 2010 | intact cell/cell culture, THP-1 cells (human monocytic leukemia cell line) | DNA damage (comet assay and gamma-H2AX assay) | 1,800 MHz | 2–16 W/kg | continuous for 2 h | digital mobile phone, GSM, mobile communications, RF, PW pulsed wave, co-exposure |
Khalil AM et al. | 2012 | animal, rat/Sprague-Dawley, whole body | DNA damage/oxidative stress (urinary level of 8-hydroxy-2-deoxyguanosine) | 1,800 MHz | - | continuous for 2 h | mobile phone, GSM, mobile communications |
Vijayalaxmi et al. | 2013 | blood samples | micronuclei formation | 2,450 MHz | 10.9 W/kg | continuous for 2 h | mobile phone, UMTS, W-CDMA, mobile communications, RF, CW continuous wave, PW pulsed wave, 2.45 GHz, occupational, co-exposure |
Atli Sekeroglu Z et al. | 2013 | animal, rat/Wistar albino, whole body | DNA damage, cytotoxicity | 900 MHz | 0.37–0.76 W/kg | continuous for 2 h/day for 45 days | mobile phone, GSM, mobile communications, RF, CW continuous wave |
Deshmukh PS et al. | 2015 | animal, rat/Fischer 344, whole body | cognitive function, Hsp70 protein expression and DNA damage in the rat brain | 900 MHz | 0.5853–0.6672 mW/kg | continuous for 2 h/day, 5 days/week for 180 days | mobile communications, microwaves, 2.45 GHz |
Ziemann C et al. | 2009 | animal, mouse/B6C3F1/CrlBR, whole body | formation of micronuclei | 902 MHz | 0.14–4 W/kg | continuous for 2 h/day, 5 days/weeks for 2 years (see also add. information for exp. setup) | mobile communications, digital mobile phone, GSM |