Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Cao Y et al. | 2009 | intact cell/cell culture, SHG44 cells (human glioma cells) | oxidative stress, cell proliferation, cell cycle distribution, apoptosis | 900 MHz | - | continuous for 2 h/day on 3 days | mobile phone, mobile communications, co-exposure |
Lin YY et al. | 2017 | intact cell/cell culture, TM3 cells (mouse Leydig cell line) | - | 1,950 MHz | - | - | mobile communications, GSM, RF |
Daus AW et al. | 2011 | intact cell/cell culture, chicken cardiac myocyte spheroids | electrophysiological properties of myocytes | 900 MHz | 100 mW/kg–1 W/kg | continuous for 1 min | mobile phone, mobile communications, RF, PW pulsed wave |
Ruan P et al. | 2012 | intact cell/cell culture, erythrocytes | - | 900 MHz | 6.24 mW/kg–2.08 W/kg | - | mobile phone, mobile phone base station, GSM, mobile communications, radar |
Kouzmanova M et al. | 2007 | intact cell/cell culture, erythrocytes suspension | membrane stability | 902 MHz | - | continuous for 20 min | digital mobile phone, GSM, mobile communications |
Linz KW et al. | 1999 | intact cell/cell culture, guinea pig, rat | electrical characteristics of excitable cells (membrane potential; whole cell current) | 180 MHz | 15–880 mW/kg | continuous for 2 min | GSM, mobile communications |
Xu S et al. | 2006 | intact cell/cell culture, hippocampal neurons | activity and functional changes of glutamate receptor channels | 1,800 MHz | 2.4 W/kg | repeated daily exposure, 15 min/day, for 8 days | digital mobile phone, GSM, mobile communications, microwaves |
Esmekaya MA et al. | 2013 | intact cell/cell culture, human breast fibroblasts | cell viability, apoptosis, mitochondrial membrane potential | 2.1 GHz | 0.607 W/kg | continuous for 4 or 24 hours | W-CDMA, mobile communications, microwaves |
Chowdhury A et al. | 2021 | intact cell/cell culture, human erythrocytes | - | 900–1,800 MHz | - | - | mobile communications, mobile phone, GSM |
Lippi G et al. | 2016 | intact cell/cell culture, human peripheral blood | leukocyte count and neutrophil activation | 900 MHz | - | continuous for 30 minutes | mobile phone, mobile communications |