For WiMax base stations, the magnitude of the field sizes does not only depend on the existence of a line-of-sight to the antenna, but also on whether the measurement point lies inside an area within the main radiation direction of the transmitting antenna.
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 0.014–0.28 V/m (min-max value, measured) | urban area | range that results from the measurement of 311 different locations at 3.5 GHz [1] |
electric field strength | 0.12 V/m (measured) | laboratory | averaged over the height of a 191 cm tall phantom; input power: 10 mW; frequency range: 3.4 - 3.8 GHz [2] |
electric field strength | 0.67 V/m (measured) | urban area | at a distance of 10 m (line-of-sight) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on that roof; resolution bandwidth of the detector: 300 kHz [3] |
electric field strength | 0.71 V/m (measured) | urban area | at a distance of 10 m (line-of-sight) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on that roof; resolution bandwidth of the detector: 5 MHz [3] |
electric field strength | 3.05 V/m (measured) | urban area | at a distance of 5 m (within the main radiation direction) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on the roof; resolution bandwidth of the detector: 300 kHz [3] |
electric field strength | 3.4 V/m (measured) | urban area | at a distance of 5 m (within the main radiation direction) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on the roof; resolution bandwidth of the detector: 5 MHz [3] |
electric field strength | 3.51 V/m (measured) | urban area | at a distance of 2 m (within the main radiation direction) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on the roof; resolution bandwidth of the detector: 5 MHz [3] |
electric field strength | 3.78 V/m (measured) | urban area | at a distance of 2 m (within the main radiation direction) to the antenna; antenna is installed on the roof a residential building, measurements have also been performed on the roof; resolution bandwidth of the detector: 300 kHz [3] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 0.01 V/m (measured) | rural area | at a distance of 400 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.01 V/m (measured) | city outskirts | at a distance of 18 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.01 V/m (measured) | urban area | at a distance of 230 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.04 V/m (measured) | industrial park | at a distance of 330 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.04 V/m (measured) | urban area | at a distance of 46 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.06 V/m (measured) | city outskirts | at a distance of 79 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.12 V/m (measured) | rural area | at a distance of 129 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.12 V/m (measured) | urban area | at a distance of 150 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.13 V/m (measured) | city outskirts | at a distance of 236 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.14 V/m (measured) | industrial park | at a distance of 552 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.16 V/m (measured) | urban area | at a distance of 192 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.22 V/m (measured) | urban area | at a distance of 174 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.24 V/m (measured) | industrial park | at a distance of 83 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.26 V/m (measured) | industrial park | at a distance of 174 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.28 V/m (measured) | city outskirts | at a distance of 117 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.3 V/m (measured) | rural area | at a distance of 164 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.45 V/m (measured) | industrial park | at a distance of 233 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.48 V/m (measured) | rural area | at a distance of 39 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.52 V/m (measured) | rural area | at a distance of 85 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |
electric field strength | 0.84 V/m (measured) | rural area | at a distance of 5 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 0.3 µW/m² (measured) | urban area | at a distance of 230 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 0.4 µW/m² (measured) | city outskirs | at a distance of 18 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 0.5 µW/m² (measured) | rural area | at a distance of 400 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 5.2 µW/m² (measured) | urban area | at a distance of 46 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 5.3 µW/m² (measured) | industrial park | at a distance of 330 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 8.5 µW/m² (measured) | city outskirts | at a distance of 79 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 9.6 µW/m² (measured) | city outskirts | at a distance of 217 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 38.3 µW/m² (measured) | rural area | at a distance of 129 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 40.5 µW/m² (measured) | urban area | at a distance of 150 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 41.5 µW/m² (measured) | city outskirts | at a distance of 217 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 55.1 µW/m² (measured) | industrial park | at a distance of 552 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 71.8 µW/m² (measured) | urban area | at a distance of 192 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 133.2 µW/m² (measured) | urban area | at a distance of 174 m to the antenna, antenna is positioned at a height of 15 m on the roof a hospital, measurement point is located in an area within the main radiation direction of the antenna; WiMax fixed [4] |
power density | 150.7 µW/m² (measured) | industrial park | at a distance of 83 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna; WiMax fixed [4] |
power density | 184.1 µW/m² (measured) | industrial park | at a distance of 174 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is not located in an area within the main radiation direction of the antenna; WiMax fixed [4] |
power density | 206.2 µW/m² (measured) | city outskirts | at a distance of 117 m to the antenna, antenna is positioned at a height of 28 m on the roof a residential building, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 231 µW/m² (measured) | rural area | at a distance of 164 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 534.5 µW/m² (measured) | industrial park | at a distance of 233 m to two sector antennas, antennas are positioned at a height of 15 m on the roof a building, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 607.7 µW/m² (measured) | rural area | at a distance of 39 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is not located in an area within the main radiation direction of the antenna [4] |
power density | 730.6 µW/m² (measured) | rural area | at a distance of 210 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |
power density | 1,877.8 µW/m² (measured) | rural area | at a distance of 5 m to the antenna mast, antenna is positioned at a height of 8 m, measurement point is located in an area within the main radiation direction of the antenna [4] |