A ventilator is an electrically driven flow machine that generates an airflow with the help of a moving rotor.
Due to the operation with an electric motor, alternating electric and magnetic fields can occur even in the kHz region.
Measurand | Value | Feature | Remarks |
---|---|---|---|
magnetic flux density | 0.1 µT (mean, measured) | - | at a distance of 60.96 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 0.3 µT (mean, measured) | - | at a distance of 30.48 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 0.4 µT (maximum, measured) | - | at a distance of 121.92 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 0.6 µT (maximum, measured) | - | at a distance of 60.96 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 2 µT (maximum, measured) | - | at a distance of 30.48 cm; examined frequency: 60 Hz [1] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 1.51 kV/m (maximum) | - | at the surface of the device at 50 Hz [2] |
magnetic flux density | 1 µT (maximum) | - | maximum value at a distance of 80 cm; examined frequency: 50 Hz resp. 60 Hz [3] |
magnetic flux density | 8 µT (maximum) | - | maximum value at a distance of 40 cm; examined frequency: 50 Hz resp. 60 Hz [3] |
magnetic flux density | 10.5 µT (maximum) | - | maximum value directly in front of the device; examined frequency: 50 Hz bzw. 60 Hz [3] |
magnetic flux density | 30–4,000 µT (maximum) | - | measurement span of 15 table fans; measurement bandwidth: 5 Hz - 2 kHz [4] |
magnetic flux density | 637 µT (maximum) | - | at the surface of the device at 50 Hz [5] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
magnetic flux density | 0.1 µT (maximum, measured) | - | at a distance of 121.92 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 0.3 µT (mean, measured) | - | at a distance of 30.48 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 0.5 µT (maximum) | - | at a distance of 80 cm; examined frequency: 50 Hz bzw. 60 Hz [3] |
magnetic flux density | 0.6 µT (maximum, measured) | - | at a distance of 60.96 cm; examined frequency: 60 Hz [1] |
magnetic flux density | 1.3 µT (mean, measured) | - | average of 4 devices at a distance of 50 cm; measurement bandwidth: 0 - 3000 Hz [6] |
magnetic flux density | 2.5 µT (maximum) | - | at a distance of 40 cm; examined frequency: 50 Hz bzw. 60 Hz [3] |
magnetic flux density | 5 µT (maximum, measured) | - | at a distance of 30.48 cm: examined frequency: 60 Hz [1] |
magnetic flux density | 6.5 µT (maximum) | - | directly beneath the device; examined frequency: 50 Hz resp. 60 Hz [3] |
magnetic flux density | 10.26 µT (mean, measured) | - | average of 4 devices at a distance of 10 cm; measurement bandwidth: 0 - 3000 Hz [6] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
magnetic flux density | 13.83 nT (maximum) | - | spatially averaged value at distances from 30 cm - 3.05 m; examined frequency: 60 Hz [7] |