FM radio broadcast towers send radio waves in the frequency range between 97.5 - 108 MHz. They are used to transmit radio programms.
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 0.046–0.27 µV/m (maximum) | - | in a car park in Ghana [1] |
electric field strength | 0.54 mV/m (maximum) | - | measured in Ghana on a commercial plaza [1] |
electric field strength | 0.1 V/m (maximum) | - | maximum measured value [2] |
electric field strength | 0.26 V/m (maximum) | - | measured inside an office during the day [3] |
electric field strength | 0.62 V/m (maximum) | - | maximum value out of 55 measuring sights in a suburban area [4] |
electric field strength | 1.17 V/m (maximum) | - | maximum value out of 77 measuring sights in an urban area [4] |
electric field strength | 1.44 V/m (maximum) | - | maximum value out of 311 measuring sites [4] |
electric field strength | 1.44 V/m (maximum) | - | maximum value out of 47 measuring sights in a residential area [4] |
electric field strength | 2–200 V/m (maximum) | - | at groundlevel with varying distance [5] |
electric field strength | 3.6 V/m (mean, measured) | - | field measurement at emission tower A with a FM-VHF 91 MHz signal of transmission tower B in 20 m distance. Measurement spot at the temporal working place of a maintenance worker. Rms-value averaged over 6 minutes. [6] |
electric field strength | 4 V/m (maximum) | - | public exposure at 1500 m from a 300 kW FM mast [7] |
magnetic flux density | 0.01 µT (maximum) | - | maximum value at a distance of 1 m [8] |
magnetic flux density | 1 µT (maximum) | - | at a distance of 30 cm [8] |
magnetic flux density | 16–56 µT (maximum) | - | at a distance of 3 cm [8] |
power density | 0.25 nW/m² (maximum) | - | maximum value out of 20 base stations in Ghana [1] |
power density | 0.133 µW/m² (maximum) | - | median value [9] |
power density | 1.1 µW/m² (measured) | - | in rural areas of Sweden [10] |
power density | 6.63–12.63 µW/m² (maximum) | - | mean values (dependent on measurement approach) from the 5th story up [2] |
power density | 0.01 mW/m² (maximum) | - | with additional phone call [11] |
power density | 13 µW/m² (measured) | - | in the capital of Sweden (Stockholm) [10] |
power density | 19.19 µW/m² (measured) | - | averaged over 130 measurement points in 2006 [12] |
power density | 31.86 µW/m² (measured) | - | averaged over 130 measurement points in 2009 [12] |
power density | 35.65 µW/m² (measured) | - | averaged over 213 measurement points in 2009 [12] |
power density | 40 µW/m² (maximum) | - | - [9] |
power density | 47 µW/m² (measured) | - | in urban areas of Sweden [10] |
power density | 50 W/m² (maximum) | - | as regards a dipole-panel antenna [13] |
SAR | 29.77 µW/kg (maximum) | - | max. value, whole-body SAR of 1-year-old child [3] |
power | 0–0.1 kW (maximum) | - | concern 150 out of 350 measuring sights [7] |
power | 10–50 kW (maximum) | - | input power of a single antenna [13] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 0.097 V/m (mean, measured) | - | mean exposure of 40 different locations within various buildings in Greece; per location 11 measurements were performed: three in the center of the room at different heights (1.1 m, 1.5 m, 1.7 m), four in the corners of the room at a distance of 1 m from the center and a height of 1 m, three next to the window and one at the position of the maximum electric field. [14] |
electric field strength | 0.18 V/m (mean, measured) | - | averaged maximum value measured at 13 different locations within a building in a suburban area in Greece [14] |
electric field strength | 0.23 V/m (maximum, measured) | - | averaged maximum value measured at 27 different locations within a building in an urban area in Greece [14] |
electric field strength | 0.31 V/m (maximum, measured) | - | averaged maximum exposure of 40 different locations within various buildings in Greece; per location 11 measurements were performed: three in the center of the room at different heights (1.1 m, 1.5 m, 1.7 m), four in the corners of the room at a distance of 1 m from the center and a height of 1 m, three next to the window and one at the position of the maximum electric field. [14] |