Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2053 studies in total
  1. 765 studies
  2. 637 studies
  3. 517 studies
  4. 414 studies
  5. 330 studies
  6. 208 studies

Cell functions

330 studies in total
  1. 124 studies
  2. 102 studies
  3. 85 studies
  4. 67 studies

General cell functions 124 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Patruno A et al. 2010 intact cell/cell culture, HaCaT cells (human keratinocytes) magnetic field, low frequency, 50/60 Hz, electrotherapy 1 mT
Sołek P et al. 2022 intact cell/cell culture, HeLa cells (human adenocarcinoma cell line) and DU 145 cells (human prostate cancer cell line) magnetic field, signals/pulses, 50/60 Hz, also other exposures without EMF, co-exposure -
Nindl G et al. 1997 intact cell/cell culture, Jurkat cells (clone E6-1; T-lymphocyte hybridoma cell line) magnetic field, signals/pulses, 50/60 Hz 0.1–1.8 mT
Jacobi-Elizondo JS et al. 2001 intact cell/cell culture, L5178Y-R cells (mouse lymphoma cell line), animal, mouse/BALB/c, whole body magnetic field, 50/60 Hz 1 mT
Shibaki R et al. 2022 intact cell/cell culture, MES-SA and MES-SA/DxS cells (human uterine sarcoma cell lines) magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF -
Percherancier Y et al. 2015 intact cell/cell culture, NIH3T3 cells (mouse fibroblasts) magnetic field, 50/60 Hz 0.4–1 mT
Saito A et al. 2009 intact cell/cell culture, P19 cells (mouse embryonal carcinoma cells) magnetic field, low frequency, 50/60 Hz 1–10 mT
Morabito C et al. 2010 intact cell/cell culture, PC-12 cells magnetic field, low frequency, 50/60 Hz 0.1–1 mT
Opler M et al. 1997 intact cell/cell culture, PC-12 cells (pheochromocytoma cell line from rat adrenal gland) magnetic field, 50/60 Hz 6.7–8 µT
Hwang YH et al. 2011 intact cell/cell culture, RBL-2H3 (rat basophilic leukemia cells) magnetic field, low frequency, 50/60 Hz 0.1–1 mT
Yamaguchi DT et al. 2002 intact cell/cell culture, ROS 17/2.8 (osteoblast-like cells) and MC3T3-E1 cells (mouse osteoblast-like cells) magnetic field, low frequency, 50/60 Hz, therapeutic/medical device 0.6–1.25 mT
Wang Z et al. 2024 intact cell/cell culture, RSC96 cells, animal, rat/Sprague Dawley 50/60 Hz, magnetic field, signals/pulses, also other exposures without EMF, co-exposure -
Calabro E et al. 2013 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, 50/60 Hz 0.05–1.41 mT
Reale M et al. 2014 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, 50/60 Hz, co-exposure 1 mT
Calabrò E et al. 2019 intact cell/cell culture, SH-SY5Y cells (human neuroblastoma cell line) static magnetic field, 50/60 Hz, magnetic field, DC -
Destefanis M et al. 2015 intact cell/cell culture, SKBR3 (human breast cancer cells), GTL16 (human gastric cancer cells), HT29 (human colon cancer cells), A375P (human melanoma cells) magnetic field, 50/60 Hz 12 µT
Schimmelpfeng J et al. 1993 intact cell/cell culture, SV40-swiss-3T3 cells (mouse fibroblast cell line) electric field, magnetic field, 50/60 Hz 2 mT
Colciago A et al. 2024 intact cell/cell culture, Schwann cells (from sciatic nerves of neonatal rats) magnetic field, 50/60 Hz -
Su L et al. 2017 intact cell/cell culture, U251 and A127 (human glioblastoma cell lines), SH-SY5Y (human neuroblastoma cell line), rat astrocytes, rat microglia, primary cortical neurons (of rat) magnetic field, low frequency, 50/60 Hz 2 mT
Golfert F et al. 2001 intact cell/cell culture, astrocytes (from neonatal rat brain) magnetic field, 50/60 Hz, co-exposure 100–200 µT
Akan Z et al. 2010 intact cell/cell culture, bacterium, THP-1 cells (human monocytic leukemia cell line) and <i>Staphylococcus aureus</i> magnetic field, low frequency, 50/60 Hz, co-exposure 1–5 mT
Tabrah FL et al. 1978 intact cell/cell culture, ciliate/slipper animalcule (<i>Tetrahymena pyriformis</i>) magnetic field, 50/60 Hz 6–10 mT
Parkinson WC et al. 1992 intact cell/cell culture, diatom (<i>Amphora coffeiformis</i>) magnetic field, low frequency, 50/60 Hz, DC, static magnetic field 20.9–85 µT
Kula B et al. 1996 intact cell/cell culture, fibroblasts magnetic field, static magnetic field, low frequency, 50/60 Hz 20–490 mT
He YL et al. 2013 intact cell/cell culture, granule cells magnetic field, 50/60 Hz 0.4–1 mT