Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2073 studies in total
  1. 775 studies
  2. 644 studies
  3. 523 studies
  4. 418 studies
  5. 333 studies
  6. 211 studies

Cell functions

333 studies in total
  1. 126 studies
  2. 102 studies
  3. 85 studies
  4. 68 studies

(Intracellular) calcium concentration 68 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Nishimura I et al. 1999 intact cell/cell culture, rat/Sprague Dawley SPF (thymocytes and spleenocytes and peripheral blood lymphocytes) magnetic field, 50/60 Hz 0.1–5 mT
Galvanovskis J et al. 1999 intact cell/cell culture, Jurkat cells (clone E6-1; T-lymphocyte hybridoma cell line) magnetic field, 50/60 Hz 50–400 µT
Morgado-Valle C et al. 1998 intact cell/cell culture, chromaffin cells (from postnatal Wistar rat adrenal medulla) magnetic field, 50/60 Hz, co-exposure 700 µT
Lindstrom E et al. 1998 intact cell/cell culture, Jurkat cells (T-lymphocyte hybridoma cell line; clone E6-1 wild type and four derivative clones) magnetic field, 50/60 Hz 100–150 µT
Lyle DB et al. 1997 intact cell/cell culture, Jurkat cells (clone E6-1; T-lymphocyte hybridoma cell line) magnetic field, 50/60 Hz 150 µT
Galvanovskis J et al. 1996 intact cell/cell culture, Jurkat cells (clone E6-1; T-lymphocyte hybridoma cell line) magnetic field, 50/60 Hz 100 µT
Barbier E et al. 1996 intact cell/cell culture, rat/Wistar (rat pituirary cells) magnetic field, 50/60 Hz 50 µT
Korzh-Sleptsova IL et al. 1995 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) magnetic field, 50/60 Hz 100–150 µT
Lindstrom E et al. 1995 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) magnetic field, 50/60 Hz 64–150 µT
Lindstrom E et al. 1995 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) magnetic field, low frequency, 50/60 Hz 40–150 µT
Karabakhtsian R et al. 1994 intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells) magnetic field, 50/60 Hz 8 µT
Liburdy RP et al. 1993 intact cell/cell culture, rat/Sprague-Dawley (thymic lymphocytes) magnetic field, 50/60 Hz 22 mT
Coulton LA et al. 1993 intact cell/cell culture, T-lymphocytes isolated from BALB/c mouse thymus magnetic field, low frequency, 50/60 Hz, DC, static magnetic field 20.9–65.3 µT
Lindstrom E et al. 1993 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) magnetic field, 50/60 Hz 100 µT
Liburdy RP 1992 intact cell/cell culture, T-lymphocytes isolated from Sprague-Dawley rat thymus and human peripheral blood lymphocytes RF, electric field, magnetic field, static magnetic field, 50/60 Hz, MRI 64 µT–2.35 T
Yost MG et al. 1992 intact cell/cell culture, rat lymphocytes magnetic field, static magnetic field, low frequency, 50/60 Hz 23.4–42.1 µT
Liburdy RP 1992 intact cell/cell culture, rat lymphocytes electric field, magnetic field, 50/60 Hz, co-exposure 22 mT
Walleczek J et al. 1990 intact cell/cell culture, rat thymocytes magnetic field, 50/60 Hz, co-exposure 22 T