Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Study type | Study group | Observation period | Study location | Endpoints | Parameters |
---|---|---|---|---|---|---|---|
Broadbent DE et al. | 1985 | cross-sectional study | men | not stated | UK | headache, anxiety, obsessional and somatic symptoms, depression, health status: visits to medical doctor, prescribed and unprescribed medicine | electric field, 50/60 Hz, power transmission line, electrical substation, occupational |
Sandström M et al. | 1995 | case-control study | men, women | October - December 1988 | Sweden | skin symptoms: itching, stinging, tight or burning sensation on facial skin, dry and/or flushed facial skin | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Stenberg B et al. | 2002 | survey | men, women | 1980 - 1998 | Sweden | facial skin symptoms, general symptoms (e.g., fatigue), neurological symptoms (e.g., dizziness), cognitive symptoms (e.g., memory loss) | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Stenberg B et al. | 1995 | case-control study | men, women, 21–59 years | January - April 1989 | Sweden | facial skin symptoms | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational, also other exposures without EMF |
Bergdahl J | 1995 | case-control study | men, women, 30–56 years | not stated | Sweden | electromagnetic hypersensitivity, psychological characteristics | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational, personal, also other exposures without EMF |
Barsam T et al. | 2012 | case-control study | men, 24–57 years | not stated | Iran | sleep quality | electric field, magnetic field, 50/60 Hz, electrical substation, occupational |
Dowson DI et al. | 1988 | cross-sectional study | men, women | not stated | UK | headache, migraine, depression | electric field, magnetic field, 50/60 Hz, power transmission line, residential |
Hillert L et al. | 2002 | cross-sectional study | men, women, 19–80 years | 1997 | Sweden | hypersensitivity to electric or magnetic fields (facial skin problems, eye irritation, runny or stuffy nose, impaired sense of smell, hoarse or dry throat, coughing, sense of pressure in the ear, fatigue, sense of heaviness in head, headache, nausea or dizziness, difficulties to concentrate) | electric field, magnetic field, 50/60 Hz, residential, personal, also other exposures without EMF |
Rizi HAY et al. | 2013 | - | men, 40–50 years | not stated | Iran | attention disorders, difficulties in concentration, headache, fatigue, nervousness, palpitations, vertigo and dizziness, somatization, obsession and compulsion, interpersonal sensitivity, depression, anxiety, hostility, phobic anxiety, paranoid ideation and psychotic symptoms | electric field, magnetic field, low frequency, 50/60 Hz, power transmission line, electrical substation, occupational |
Liden S et al. | 1991 | - | men, women | - | Sweden | skin problems e.g. rosacea, atopic dermatitis, acne | magnetic field, 50/60 Hz, PC/TV monitor |