Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Burch JB et al. | 2002 | human, whole body | melatonin excretion | 60 Hz | - | total daily exposure of 1-10, 11-25, or >25 min/day for 3 days | mobile communications, analog mobile phone, 50/60 Hz, power transmission line, electrical substation |
de Seze R et al. | 2001 | human, partial body: head (left or right side) | effects on nervous system, auditory system, and endocrine system | 900 MHz | - | continuous for 1 h | mobile communications, digital mobile phone, GSM, microwaves |
Bastide M et al. | 2001 | animal, chicken embryos (eggs) and chicks, mouse/C57BL/6 j RJ, whole body | cancer in mice, hormone levels in chicken and mice, antibody levels in chicken, mortality in chicken embryos | 900 MHz | - | continuous for up to 15 weeks | mobile phone, GSM, mobile communications, magnetic field, low frequency, 50/60 Hz, PC/TV monitor, shielding/field deprivation |
Shrivastava A et al. | 2014 | human | melatonin concentration in the blood | - | - | more than 2 hours/day of mobile phone usage | mobile phone, GSM, mobile communications |
Sallam AED et al. | 2016 | animal, rat/Sprague-Dawley, whole body | - | 900 MHz | - | - | mobile communications, mobile phone |
Sukhotina I et al. | 2006 | pineal glands | melatonin synthesis | 1,800 MHz | 8–2,700 mW/kg | continuous for 7 h | GSM, mobile communications |
Radon K et al. | 2001 | human, partial body: head | levels of salivary melatonin, cortisol, neopterin, and immunoglobulin A | 900 MHz | 0.025 W/kg | continuous for 4 h | digital mobile phone, GSM, mobile communications |
Vollrath L et al. | 1997 | animal, rat/Sprague-Dawley and Dark Agouti; hamster/Djungarian, whole body | effects on pineal gland (melatonin level) | 900 MHz | 0.04–0.36 W/kg | continuous for 15, 30, or 60 min | GSM, mobile communications |
Bakos J et al. | 2003 | animal, rat/Wistar, whole body | amount of 6-sulphatoxymelatonin in excreted urine | 900 MHz | 0.045 W/kg–0.012 W/g | repeated daily exposure of 2 h/day for 14 days | GSM, mobile communications, microwaves |
Cao H et al. | 2015 | animal, rat/Sprague-Dawley, whole body | circadian concentration of melatonin, superoxide dismutase and glutathione peroxidase in blood | 1.8 GHz | 0.05653 W/kg | continuous for 2 h/day for 32 days | mobile phone, mobile communications |