Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Verrender A et al. | 2018 | human, whole body | symptoms and field perception | 902–928 MHz | - | 30 min each exposure (6 x in double-blind study) | GSM, UMTS, mobile communications, RF, W-LAN/WiFi |
Radon K et al. | 1998 | human, whole body | perception of electromagnetic fields | 900 MHz | - | repeated exposure with intermittent stimulus (3 x 2 min on/10 s off) for 12 times in one day | GSM, mobile communications |
Wilen J et al. | 2006 | human, partial body: head | physiological and cognitive responses | 900 MHz | 0.8–1 W/kg | continuous for 30 min | GSM, mobile communications |
Rubin GJ et al. | 2006 | human, partial body: head (left ear) | subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) | 900 MHz | 1.4 W/kg | continuous for 50 min | GSM, mobile communications, mobile phone |
Sauter C et al. | 2015 | human, partial body: left side of the head | working memory and attention, well-being | 385 MHz | 1.5–6 W/kg | continuous for 2.5 hours | TETRA/TETRAPOL, mobile communications |
Bolte JFB et al. | 2019 | human | - | - | - | - | TETRA/TETRAPOL, mobile communications, GSM, mobile phone, mobile phone base station, UMTS, RF, W-LAN/WiFi, FM broadcast (UKW), Radio/TV transmitter, DECT, personal |
Dorn H et al. | 2014 | human, partial body: head/ear | warmth perception, skin temperature | 385 MHz | 1.5–6 W/kg | continuous for 30 minutes | TETRA/TETRAPOL, mobile communications, PW pulsed wave |
Hietanen M et al. | 2002 | human, partial body: head | electromagnetic hypersensitivity symptoms or sensations | 900 MHz | - | repeated exposure for less than 30 min, see add. information | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |
Braune S et al. | 1998 | human, partial body: head (right side) | blood pressure, heart rate, capillary perfusion, well-being | 900 MHz | - | continuous for 35 min | digital mobile phone, GSM, mobile communications |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.