Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1743 studies in total
  1. 770 studies
  2. 584 studies
  3. 519 studies
  4. 228 studies
  5. 208 studies
  6. 118 studies

Health

770 studies in total
  1. 157 studies
  2. 95 studies
  3. 86 studies
  4. 84 studies
  5. 80 studies
  6. 62 studies
  7. 59 studies
  8. 55 studies
  9. 54 studies
  10. 48 studies
  11. 34 studies
  12. 28 studies
  13. 26 studies
  14. 19 studies
  15. 16 studies
  16. 11 studies
  17. 9 studies
  18. 4 studies
Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Nieto-Hernandez R et al. 2011 human, partial body: head (left ear) mood and symptoms 385.25 MHz 0.3–1.3 W/kg continuous for 50 min mobile communications, TETRA/TETRAPOL, RF, CW continuous wave, PW pulsed wave
Wilen J et al. 2006 human, partial body: head physiological and cognitive responses 900 MHz 0.8–1 W/kg continuous for 30 min GSM, mobile communications
Oftedal G et al. 2007 human, partial body: head headache 902.4 MHz 0.8–1 W/kg continuous for 30 min digital mobile phone, GSM, mobile communications
Kwon MS et al. 2008 human, partial body: ear electrosensibility 902 MHz 0.82–1.21 W/kg intermittent, 5 s on or off and a pause for reaction plus 1 s, repeated 100 times digital mobile phone, GSM, mobile communications
Stovner LJ et al. 2008 human, partial body: head headache 902.4 MHz 1 W/kg continuous for 30 min mobile phone, digital mobile phone, GSM, mobile communications, RF
Nam KC et al. 2009 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure 824.64–848.37 MHz 1.22 W/kg continuous for 30 min mobile communications, digital mobile phone, CDMA
Rubin GJ et al. 2006 human, partial body: head (left ear) subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) 900 MHz 1.4 W/kg continuous for 50 min GSM, mobile communications, mobile phone
Cinel C et al. 2008 human, partial body: left or right side of the head subjective symptoms 888 MHz 1.4–11.2 W/kg continuous for 40 min digital mobile phone, GSM, mobile communications
Dorn H et al. 2014 human, partial body: head/ear warmth perception, skin temperature 385 MHz 1.5–6 W/kg continuous for 30 minutes TETRA/TETRAPOL, mobile communications, PW pulsed wave
Sauter C et al. 2015 human, partial body: left side of the head working memory and attention, well-being 385 MHz 1.5–6 W/kg continuous for 2.5 hours TETRA/TETRAPOL, mobile communications