Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Kwon MS et al. | 2008 | human, partial body: ear | electrosensibility | 902 MHz | 0.82–1.21 W/kg | intermittent, 5 s on or off and a pause for reaction plus 1 s, repeated 100 times | digital mobile phone, GSM, mobile communications |
Hietanen M et al. | 2002 | human, partial body: head | electromagnetic hypersensitivity symptoms or sensations | 900 MHz | - | repeated exposure for less than 30 min, see add. information | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Wilen J et al. | 2006 | human, partial body: head | physiological and cognitive responses | 900 MHz | 0.8–1 W/kg | continuous for 30 min | GSM, mobile communications |
Oftedal G et al. | 2007 | human, partial body: head | headache | 902.4 MHz | 0.8–1 W/kg | continuous for 30 min | digital mobile phone, GSM, mobile communications |
Stovner LJ et al. | 2008 | human, partial body: head | headache | 902.4 MHz | 1 W/kg | continuous for 30 min | mobile phone, digital mobile phone, GSM, mobile communications, RF |
Kim DW et al. | 2008 | human, partial body: head | pulse rate, heart rate variability, heart rate, respiratory rate | 824.64–848.37 MHz | 1.6 W/kg | continuous for 31 min | mobile communications, mobile phone, CDMA |
Nam KC et al. | 2009 | human, partial body: head | pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure | 824.64–848.37 MHz | 1.22 W/kg | continuous for 30 min | mobile communications, digital mobile phone, CDMA |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.6 W/kg | continuous for 32 min | digital mobile phone, W-CDMA, mobile communications, microwaves |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.57 W/kg | - | mobile phone, W-CDMA, mobile communications |
Rubin GJ et al. | 2006 | human, partial body: head (left ear) | subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) | 900 MHz | 1.4 W/kg | continuous for 50 min | GSM, mobile communications, mobile phone |