Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Verrender A et al. | 2018 | human, whole body | symptoms and field perception | 902–928 MHz | - | 30 min each exposure (6 x in double-blind study) | GSM, UMTS, mobile communications, RF field, W-LAN/WiFi |
Radon K et al. | 1998 | human, whole body | perception of electromagnetic fields | 900 MHz | - | repeated exposure with intermittent stimulus (3 x 2 min on/10 s off) for 12 times in one day | GSM, mobile communications |
Wilen J et al. | 2006 | human, partial body: head | physiological and cognitive responses | 900 MHz | 0.8–1 W/kg | continuous for 30 min | GSM, mobile communications |
Rubin GJ et al. | 2006 | human, partial body: head (left ear) | subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) | 900 MHz | 1.4 W/kg | continuous for 50 min | GSM, mobile communications, mobile phone |
Sauter C et al. | 2015 | human, partial body: left side of the head | working memory and attention, well-being | 385 MHz | 1.5–6 W/kg | continuous for 2.5 hours | TETRA/TETRAPOL, mobile communications |
Bolte JFB et al. | 2019 | human | - | - | - | - | TETRA/TETRAPOL, mobile communications, GSM, mobile phone, mobile phone base station, UMTS, RF field, W-LAN/WiFi, FM broadcast (UKW), Radio/TV transmitter, DECT, personal |
Dorn H et al. | 2014 | human, partial body: head/ear | warmth perception, skin temperature | 385 MHz | 1.5–6 W/kg | continuous for 30 minutes | TETRA/TETRAPOL, mobile communications, PW pulsed wave |
Hietanen M et al. | 2002 | human, partial body: head | electromagnetic hypersensitivity symptoms or sensations | 900 MHz | - | repeated exposure for less than 30 min, see add. information | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |
Braune S et al. | 1998 | human, partial body: head (right side) | blood pressure, heart rate, capillary perfusion, well-being | 900 MHz | - | continuous for 35 min | digital mobile phone, GSM, mobile communications |
Koivisto M et al. | 2001 | human, partial body: head (left side) | subjective symptoms or sensations | 902 MHz | - | 1 session of 30 min or 2 sessions of 60 min each separated by 24 h | digital mobile phone, GSM, mobile communications |
Oftedal G et al. | 2007 | human, partial body: head | headache | 902.4 MHz | 0.8–1 W/kg | continuous for 30 min | digital mobile phone, GSM, mobile communications |
Kwon MS et al. | 2008 | human, partial body: ear | electrosensibility | 902 MHz | 0.82–1.21 W/kg | intermittent, 5 s on or off and a pause for reaction plus 1 s, repeated 100 times | digital mobile phone, GSM, mobile communications |
Hillert L et al. | 2008 | human, partial body: head (left side) | electromagnetic field perception and symptoms (headache, vertigo, skin irritation and sensation of heat) | 884 MHz | 0.18–1.8 W/kg | continuous for 3 h | digital mobile phone, GSM, mobile communications |
Cinel C et al. | 2008 | human, partial body: left or right side of the head | subjective symptoms | 888 MHz | 1.4–11.2 W/kg | continuous for 40 min | digital mobile phone, GSM, mobile communications |
Mortazavi SM et al. | 2011 | human | - | - | - | continuous for 10 min | digital mobile phone, GSM, mobile communications, microwaves |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.6 W/kg | continuous for 32 min | digital mobile phone, W-CDMA, mobile communications, microwaves |
Furubayashi T et al. | 2009 | human, whole body | mobile phone related symptoms (e.g. heart rate, psychological parameters, skin surface temperature) | 2.14 GHz | 0.0013–0.019 W/kg | continuous for 30 min | digital mobile phone, mobile phone base station, CDMA, mobile communications |
Eger H | 2014 | - | - | - | - | - | mobile communications |
Dömötör Z et al. | 2022 | human | - | - | - | - | mobile communications, GSM, UMTS, TETRA/TETRAPOL, mobile phone, mobile phone base station, RF field, DECT, W-LAN/WiFi, Radio/TV transmitter, FM broadcast (UKW) |
Verrender A et al. | 2018 | human | - | 902–928 MHz | - | - | mobile communications, RF field, W-LAN/WiFi |
Nieto-Hernandez R et al. | 2011 | human, partial body: head (left ear) | mood and symptoms | 385.25 MHz | 0.3–1.3 W/kg | continuous for 50 min | mobile communications, TETRA/TETRAPOL, RF field, CW continuous wave, PW pulsed wave |
Wallace D et al. | 2010 | human, whole body | electrosensitivity (well-being and different physiological responses) | 420 MHz | 271 µW/kg | continuous for 15 min for the open provocation test, 2 times 5 min for the doble blind test | mobile communications, TETRA/TETRAPOL, TDMA, RF field |
Nam KC et al. | 2009 | human, partial body: head | pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure | 824.64–848.37 MHz | 1.22 W/kg | continuous for 30 min | mobile communications, digital mobile phone, CDMA |
Kaul G | 2009 | human, whole body, partial body: 30 cm from the head (in the case of GSM) | field perception | 50 Hz | 0.75 µW/g | 3 times 10 min | mobile communications, digital mobile phone, GSM, magnetic field, 50/60 Hz |