Epidemiological studies of low and radio frequency exposure on children's health comprise the following studies:
Authors | Year | Study type | Study group | Observation period | Study location | Endpoints | Parameters |
---|---|---|---|---|---|---|---|
Parazzini F et al. | 1993 | meta-analysis | women, children in utero, newborns | 1976 - 1987 | USA, Canada, Sweden, Denmark, Finland | miscarriage, low birth weight, and congenital malformation | magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Nielsen CV et al. | 1992 | case-control study | women, children in utero, newborns | 1984 - 1985 | Denmark | low birthweight, preterm birth, infant mortality | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Dlugosz L et al. | 1992 | case-control study | women, children in utero, newborns | 1988 - 1989 | USA | congenital defects | magnetic field, 50/60 Hz, electric blanket, other domestic appliance, personal |
Lindbohm ML et al. | 1992 | case-control study | women, children in utero | 1975 - 1985 | Finland | spontaneous abortion | magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Schnorr TM et al. | 1991 | cohort study | women, children in utero | 1983 - 1986 | USA | spontaneous abortion | magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Tikkanen J et al. | 1990 | case-control study | women, children in utero, newborns | 1982 - 1984 | Finland | cardiovascular malformations | magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Brandt LP et al. | 1990 | case-control study | women, children in utero, newborns | 1984 - 1985 | Denmark | congenital malformations | magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Windham GC et al. | 1990 | case-control study | women, children in utero, newborns | 1986 - 1987 | USA | spontaneous abortion, low birthweight, and intrauterine growth retardation | electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational |
Bryant HE et al. | 1989 | case-control study | women, children in utero | January 1984 - April 1985 | Canada | spontaneous abortion | magnetic field, 50/60 Hz, PC/TV monitor, personal |
Nurminen T et al. | 1988 | case-control study | women, children in utero, newborns | 1976 - 1982 | Finland | threatened abortion, length of gestation, birthweight, placental weight, and maternal blood pressure | magnetic field, 50/60 Hz, PC/TV monitor, occupational |